Interchange SM4018V Manual Del Operador página 12

Grapadora de corona medio calibre 18
Tabla de contenido

Publicidad

SM4018V
12
OPERATING THE TOOL
CONNECTIONS
Fittings
1
1
ƒ Install a female coupler to the hose. The female coupler
will connect to the quick release that fits the tool.
Filter-Regulator-Lubricator
ƒ Never connect tool to pressure that potentially exceeds
175psi or 12 bar.
ƒ Filter-regulator-lubricator units supply an optimum
condition for the tool and extend the tool life. These units
should always be used.
Filter
ƒ The filter removes moisture and dirt mixed in
compressed air.
ƒ Keep the filter clean by maintaining tool regularly.
ƒ Drain daily.
2
Regulator
2
ƒ The regulator controls the operating pressure for safe
operation of the tool.
ƒ Inspect the regulator before operation to be sure it
operates properly.
Lubricator
ƒ The lubricator supplies an oil mist to the tool.
ƒ Inspect the lubricator before operation to be sure the
supply of lubricant is adequate.
ƒ If an inline lubricator is not used, a few drops of oil will
need to be added to the air inlet before each use.
3
3
Air Hose
ƒ Air hose must have a minimum working pressure rating
of 150psi (10.3 bar) or 150% of the maximum pressure
produced in the system, whichever is higher.
Interchange Brands Staplers: Operator's Manual

Publicidad

Tabla de contenido
loading

Productos relacionados para Interchange SM4018V

Este manual también es adecuado para:

65260

Tabla de contenido