EN
INSTALLATION
Hardwired Installation
Selecting a switch position
exceeding the rated current will
not exceed the rated current.
CAUTION To reduce the risk of fire, only connect
your charger to a circuit with a branch circuit
overcurrent protection of 125% of the selected max
amperage setting of the device in accordance with
ANSI/NFPA 70 (US) C22.2 NO 280 13 (Canada).
Torque: 13.3in·lbs (1.5N·m)
18
The 40A and 48A
versions are set to
position 7 by default.
Current
selector
PULSAR PLUS
Amperage Reduction Label
Wallbox Chargers S.L.U
SN: 123456
UID: abcdefgh
08/2020
22ºF to 104ºF (-30ºC to 40ºC)
PN: PUP1-U-1-5-N-002-A
Enclosure Type 4
Input/Output:
208/240VAC, 60Hz, 48A
Input/Output:
208/240VAC, 60Hz, 40A
Product Label
Circuit Breaker Label
Place the appropriate Input/Output
Label the breaker with the selected amperage value.
label on top of the charger's label.
Follow the instructions of the installation guide to select the amperage value.
Input/Output:
EV Charger
EV Charger
208/240VAC, 60Hz, 16A
20A
TM
20A
TM
Input/Output:
25A
EV Charger
EV Charger
25A
208/240VAC, 60Hz, 20A
TM
TM
Input/Output:
30A
EV Charger
EV Charger
30A
208/240VAC, 60Hz, 24A
TM
TM
Input/Output:
EV Charger
40A
EV Charger
40A
208/240VAC, 60Hz, 32A
TM
TM
Input/Output:
50A
EV Charger
50A
EV Charger
208/240VAC, 60Hz, 40A
TM
TM
Save this label
sheet for future use.
EV Charger
60A
TM
EV Charger
60A
TM
Rated current adjustment
1.
Both the 40A and 48A versions of Pulsar Plus
can be adjusted from 16A to the maximum rated
amperage of each model. If you are installing your
charger on a circuit rated lower than the maximum
rating for your charger, you can use the current
selector to manually set a lower maximum current.
Hardwire installations
2.
On your charger cover, locate the current
selector and set the rotary switch to the
appropriate setting per the chart below.
Position
Amps
2
16A
3
20A
4
24A
5
32A
6
40A
7
48A
3.
When setting your charger's current lower
than the max.rating, use the label corresponding
to your selected current value from the enclosed
amperage reduction label sheet and affix it over
the existing label on your charger.
Closing the charger
1.
Carefully reattach the communications cable
to your charger cover and close the cover of your
charger.
2.
Insert the four corner screws to secure your
charger cover. Do not over-tighten.
3.
Making sure to properly align the bottom
screw opening, place the cover frame on your
charger and attach the frame with the screw.
Do not over-tighten.
ø T20
5 x 10mm
Proceed to the instructions for installing the
holster and operating your charger, pages 18-19.
Circuit Breaker Rating
20A
25A
30A
40A
50A
60A