PROBLEM
Spray wand not in low pressure.
Will not draw
chemicals
Chemical filter clogged.
Chemical screen not in cleaning
solution.
Chemical too thick.
Pressure hose is too long
Chemical build up in chemical
injector.
Worn seal or packing
No or low
pressure
Worn or obstructed valves.
(after period
of normal
Worn unloader piston.
use)
Water leaking
Worn or broken o-ring.
at gun/
spray wand
Loose hose connection.
connection
Water
Loose connections.
leaking at
Piston packings worn.
pump
Worn or broken o-rings.
Pump head or tubes damaged
from freezing.
Pump
Pulsates
AWSC = Authorized Warranty Service Center
Recommended accessories for use with your pressure washer are available for
purchase from your local retailer or authorized service center. If you need assistance
in locating any accessory for your tool, please call
www.excellpressurewasher.com
lance/gun combination that is shorter in length than what was provided with
this pressure washer as measured from the nozzle end of the lance to the gun
trigger.
branded accessories rated equal to or greater than the rating of the pressure
washer.
A16637
CAUSE
Nozzle obstructed.
ACCESSORIES
.
Risk of fluid injection. When using replacement lances or
guns with this pressure washer, DO NOT use a lance and/or
The use of any other accessory not recommended for
use with this tool could be hazardous. Use only EXCELL
See How to Use Spray Wand
paragraph in the Operation
Section.
Clean filter.
Make sure end of chemical hose
is fully submerged into cleaning
solution.
Dilute chemical. Chemical should
be the same consistency as water.
Lengthen water supply hose
instead of high pressure hose.
Have parts cleaned or replaced
by AWSC.
Have replaced by AWSC.
Have replaced by AWSC.
Have replaced by AWSC.
Check and replace.
Tighten.
Tighten.
Have replaced by AWSC.
Have replaced by AWSC.
Have replaced by AWSC.
See Nozzle Cleaning paragraph in
the Maintenance section for the
correct procedure.