Load in VebaBox has to be placed securely. Sidewalls must
not be exposed to permanent pressure. VebaBox sidewalls
are not designed to carry permanent loads.
•
Please read the operating instructions carefully before
connecting the product.
•
Never insert objects into the ventilation openings or fans.
•
Do not obstruct air circulation by covering the grilles with
objects.
•
Do not damage any parts of the cooling system containing
refrigerants by punching, perforating, crushing, bending or
otherwise. Risk of serious frostbites from evaporating
refrigerant.
•
Follow your local regulations for hazardous substances as
refrigerants: risk of fire or explosion.
•
Never touch the heat exchanger with bare hands. Risk of
finger cuts on sharp ribs.
•
Floor might be slippery.
3. Application
The basic function of VebaBox is to maintain the goods inside it at a
regulated, stable and adjustable temperature while the box is
submitted to fluctuating ambient temperatures in the range of -20°C
to +40°C.
CAUTION: The VebaBox is not constructed for cooling goods down. This
means, that goods should be preconditioned to the required temperature before
being put into the box.
CAUTION: When loading the box, allow clearance around air intake and
outlet of the unit. Goods should be stacked to allow at least a 10 cm gap directly
below the ceiling of the box. Do not place goods directly under the heat
exchanger – risk of dripping water.
The VebaBox TUF1005 and TUF1010 is intended to be installed in
the closed superstructures of any type of cargo vans equipped with
TUF1005 and TUF1010-usm. rev.00
© 2020 VebaBox B.V. User Manual VebaBox+ TUF1005+TUF1010