The overheating cut-out will shut off the tumble dryer if the temperature
is too high, e.g. because dust is clogging the filter.
This cut-out only operates if the air flow is severely restricted so before
resetting, make sure the filter is clean and the air inlet and outlet are not
blocked.
Also, allow the dryer to cool for at least 10 minutes. To reset, press the
button at the rear of the dryer until a click is heard.
The drying process goes on too long.
Check that
- You have selected the correct programme for fabric type.
- Air inlet and outlet are not blocked.
- Clothes are not excessively wet.
- The dryer is not overloaded.
The clothes are creased.
Check that the laundry is not overloaded. Use the anti-crease function.
The garments have shrunk.
To avoid shrinkage, please follow the care and use instructions for your
garment, as some fabrics shrink naturally when washed and other fabrics
should not be placed in a dryer.
Error messages
Error
Indication
The indicator light
is flashing.
Min
The indicator lights
and
Min
are flashing.
The indicator light
is flashing.
Max
Error
Possible Cause
Description
Over temperature
NTC or PCB fault
Temperature sensor
is open or A/D
Temperature
reading under 10.
sensor error
Temperature sensor
is short or A/D
reading over 1000.
Possible Solution
Stop the
programme
and contact a
qualified
service agent.