MT-2000.book Seite 22 Freitag, 12. Mai 2006 4:55 16
Connecting the comfort indicator module
7
Connecting the comfort indicator module
The comfort indicator module is connected to the central locking with cable set 1 (6
wires). If you do not want to use the central locking confirmation function, you do not
need to connect this cable set.
Cable set 2 (5 wires) is for connecting to the vehicle indicators.
7.1
Connecting to the central locking (cable set 1)
Key for the circuit diagram for connection to the central locking:
No. in
Description
fig. 5, page 5
1
Comfort indicator module
2
6-pin plug for cable set 1
3
Terminal 30, +12 V
4
Left indicator
5
Right indicator
6
Central locking control device
7
Opening signal +12 V
8
Closing signal +12 V
rt
Red
or
Orange
ge
Yellow
gu
Green
we
White
sw
Black
➤
Insert the cable set 1 plug into the socket 1 on the comfort indicator module
(fig. 3 1, page 4).
➤
Connect the red cable to a permanent +12 V cable (terminal 30).
➤
Connect the orange cable to the right indicator wire.
➤
Connect the yellow cable to the left indicator wire.
➤
Connect the green cable to the central locking wire, where there is a brief signal
of at least +12 V when opening.
➤
Connect the white cable to the central locking wire, where there is a brief signal
of at least +12 V when closing.
➤
Connect the black cable to earth (terminal 31).
22