Descargar Imprimir esta página

Chamberlain LiftMaster PROFESSIONAL CB11 Instrucciones De Instalación página 29

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Separate table for setting the operating modes
Standard
Standard &
no self-hold (hold to run) for closing
Automatic with stop
Residential
Channel separation
Car park
No self-hold (hold to run)
DIP1
DIP2
DIP3
ON
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
Impulse transmitter/channel 1
Gate closed:
1. impulse opens, the next
one stops, the next one
closes, the next one stops,
the next one opens etc.
Impulse during closing stops
the gate
Impulse during opening stops
the gate
Impulse during the rest
closes the gate immediately
Gate closed:
1. impulse opens, the next
one stops, the next one
closes, the next one stops,
the next one opens etc.
Impulse during closing stops
the gate
Impulse during opening stops
the gate
Impulse during the rest closes
the gate immediately
Gate closed:
1. impulse opens, the next one
stops, the next one closes, the
next one opens
Gate opened:
1. impulse closes, the next one
opens
Impulse while pedestrian stops,
the next one closes
Gate closed:
1. impulse opens, the next one
closes, the next one opens, the
next one closes etc.
Impulse while pedestrian closes
the gate immediately
Impulse during automatic
closing opens the gate
immediately
Impulse during the rest closes
the gate immediately.
Gate closed:
1. impulse opens, the next one
stops, the next one opens, the
next one stops etc.
Impulse during closing stops the
gate
Gate closed:
1. impulse opens both wings
completely, further impulses are
ignored.
Impulse while pedestrian opens
the second wing as well
Impulse during closing opens the
gate immediately
Gate closed:
Permanent signal
required, letting go stops
Radio disabled, safety
equipment disabled
Impulse transmitter/channel 2
Gate closed:
1. impulse opens pedestrian
door, the next one stops, the next
one closes, the next one stops,
the next one opens etc.
Impulse during closing stops the
gate
Impulse during opening stops the
gate
Impulse during the rest closes the
gate immediately
Gate open:
Permanent signal required for
closing, letting go stops
Radio disabled, safety equipment
disabled
Gate closed:
1. impulse opens pedestrian door,
the next one stops, the next one
closes
Gate closed:
1. impulse opens pedestrian door,
the next one closes immediately
Impulse during the rest closes the
gate immediately
Gate open:
1. impulse closes, the next one
stops, the next one closes etc
Impulse during opening stops the
gate
Gate closed:
1. impulse opens pedestrian
door completely, further
impulses are ignored
Impulse during closing opens the
gate immediately
Gate open:
Permanent signal required,
letting go stops
Radio disabled, safety equipment
disabled
709438

Publicidad

loading