OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the "off"
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass
strike somebody's face during the process of lighting this unit; stand away from the unit for the first
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
Wait 50 minutes after extinguishing fame prior to placing a lid (if applicable) or protective cover on
heating item.
To Light
1. Make sure the control knob (M) is in the "OFF" position.
2. Open the door (C) and slowly open the valve on the propane gas tank by turning the knob
counterclockwise.
3. Close the door (C) on the body.
4. Push and hold in the electronic igniter (Q) to create sparks within the electrode, continue to hold.
5. Push in the control knob (M) and turn to the "LOW" position. Keep holding down the control
knob (M) to allow gas to flow for 15 seconds.
6. If ignition doesn't occur within a few seconds release the control knob (M) and rotate to the
"OFF" position. Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
7. Once the fire product is lit, the flame intensity may be controlled by turning the control knob (M)
between the "LOW" and "HIGH" positions.
To Extinguish
1. Turn control knob (M) clockwise to the "LOW" position; let the knob pop up and continue turning
the control knob (M) to the "OFF" position.
2. Close the cylinder valve on the propane gas tank if you don't intend to use it for a long time.