The H13 hepafilter can be replaced by following the same procedure as above and
unscrew some black filter clamps.
If you use the machine daily we would recommend changing the hepafilter once a
year. Of course, this depends on the contaimination of the air in the environment.
At the top of the hepafilter you will find a label with the item number (compare
this number with the number on the old filter). Make sure you place the filter as
indicated on the label :
If the H13/14 hepafilter is exposed to water, this may shorten or
pre-filters and H13/14 hepafilters cannot be cleaned and must be
The DB700 is provided with a filter indicator connected to a warning led that
measures the pressure drop in the filter. In case of a pressure drop that is too high,
the red led will light up and the hepafilter must be replaced. If the Dustblocker is
used while the warning led lights up, this could affect the operation of the device.
REPLACEMENT FILTERS
DB 700
G4 Front Filter
G3 Pre-filter
H14 Main Filter
H13 Main Filter
DB 700
Airflow
end the filter's life span.
replaced if they are saturated.
Item Nº
MV-DBF-1010
MV-DBF-1011
MV-DBF-1012
MV-DBF-1013
Replacement
1 x per week or when necessary
1 x per 3 months or when necessary.
1 x per year or when necessary.
1 x per year or when necessary.
MAX-VAC.COM