Connect the red safety measuring line to the jack for V, Ω,
teStFOX M/ M-1.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display  of the
teStFOX M/ M-1.
See figure 2:
See figure 3:
8.2.2
Current measurement ( teStFOX M-1)
-
Select the desired range and function (A AC) or (A DC) by means of the
rotary switch 8 of the teStFOX M-1.
-
Connect the black safety measuring line to the COM jack J of the
teStFOX M-1.
-
Connect the red safety measuring line to the jack for V, ,
to the jack for the 10 A range K (DC or AC currents up to 10 A) of the
teStFOX M-1.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display  of the
teStFOX M-1.
See figure 4:
See figure 5:
8.3 Resistance measurement
-
Select the desired function (Ω) by means of the rotary switch 8 of the
teStFOX M/ M-1
-
Connect the black safety measuring line to the COM jack J of the
teStFOX M/ M-1.
-
Connect the red safety measuring line to the jack for V, ,
teStFOX M/ M-1.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display  of the
teStFOX M/ M-1.
See figure 6:
8.4 Diode test
-
Select the desired function (
teStFOX M/ M-1.
-
Connect the black safety measuring line to the COM jack J of the
teStFOX M/ M-1.
-
Connect the red safety measuring line to the jack for V, ,
teStFOX M/ M-1.
-
Bring the safety measuring lines into contact with the diode connections
and read the measured value on the digital display  of the
teStFOX M/ M-1.
-
For a standard Si diode applied in conduction direction, a conduction voltage
between 0.400 V and 0.900 V is displayed. „000" indicates a short-circuit
inside the diode, „Ol" indicates an interruption inside the diode.
-
For a diode applied in reverse direction, „Ol" is indicated. if the diode is
defective, „000" or other values are indicated.
See figure 7:
8.5 Continuity test with buzzer
-
Select the desired function (
teStFOX M/ M-1.
-
Connect the black safety measuring line to the COM jack J of the
teStFOX M/ M-1.
-
Connect the red safety measuring line to the jack for V, ,
teStFOX M/ M-1.
-
Bring the safety measuring lines into contact with the measuring points. if the
line resistance between the COM jack J and the jack for V, ,
below 25 , the integrated buzzer of the teStFOX M/ M-1 sounds.
See figure 8:
8.6 Capacity measurement ( TESTFOX M-1)
Before performing capacity measurements, discharge capaci-
tors completely!
Never apply voltage to the capacity measurement jacks!
This might damage or destroy the device! A damaged device
might represent an electrical hazard!
-
Select the desired function (
teStFOX M-1.
10/ 2008
DC voltage measurement
AC voltage measurement
DC current measurement ( TESTFOX M-1)
AC current measurement ( TESTFOX M-1)
Resistance measurement
) by means of the rotary switch 8 of the
Diode test
) by means of the rotary switch 8 of the
Continuity test with buzzer
) by means of the rotary switch 8 of the
TESTFOX M/ M–1
, Hz 9 of the
, Hz 9 or
, Hz 9 of the
, Hz 9 of the
, Hz 9 of the
, Hz 9 falls
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Testfox m–1

Tabla de contenido