Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off power to the
motor to extend tool and battery life.
The tool will automatically stop during operation if the
tool or battery are placed under one of the following
conditions. In some conditions, the indicator lights up.
Overload protection
When the tool is operated in a manner that causes it to
draw an abnormally high current, the tool automatically
stops without any indications. In this situation, turn the
tool off and stop the application that caused the tool to
become overloaded. Then turn the tool on to restart.
Overheat protection for tool
When the tool is overheated, the tool stops automati-
cally and the battery indicator shows following state. In
this situation, let the tool cool before turning the tool on
again.
Battery indicator
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
► 1 . Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
On
Off
Blinking
Tool is overheated
1
Lighted
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when
the battery protection system works.
Reversing switch action
CAUTION:
Always check the direction of rotation before
operation.
Use the reversing switch only after the tool
comes to a complete stop. Changing the direc-
tion of rotation before the tool stops may dam-
age the tool.
2
► 1 . Reversing switch lever
This tool has a reversing switch to change the direc-
tion of rotation. Move the reversing switch lever
to the
position (A side) for clockwise rotation or
the
position (B side) for counterclockwise rotation.
When the reversing switch lever is in the neutral posi-
tion, the switch trigger cannot be pulled.
CAUTION:
set the reversing switch lever to the neutral position.
7 ENGLISH
Indicator lamps
Off
Blinking
B
B B
1
A
When not operating the tool, always
Remaining
capacity
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have
malfunctioned.