Order # 61505101
USE AND CARE GUIDE
LED WALLPACK INSTRUCTIONS
120-277V 50/60Hz 30W/40W/50W/60W (TWPK-1) 70W/80W/90W/100W (TWPK-2)
PACKAGE CONTENTS
Description
Quantity
Fixture
1
Foam Wall Gasket
1
Default setting is at highest wattage, 5000K CCT
NOTE: Keep your receipt and these instructions for proof of purchase.
NOTE: To avoid possibility of electrical shock or fire, the installation personnel must have professional electric knowledge; Please wear gloves to avoid injury before installation; If at some
point during or after installation you should notice smoke or fire coming from the fixture, turn the power off immediately and notify an electrician. This fixture is available for outdoor use. The
recommended minimum distance from the fixture to ground is 2 meters.
WARNING: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes. Do not use an electric generator to test the LED fixture.
Please abide by related country, regional and local law and regulations when installing this fixture; Do not install the fixture in raining days to avoid electrical shock or damage.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
APPLICATIONS: Tunnel (except for motor vehicle tunnel), workshop, warehouse,factory, house, building exterior, etc.
INSTALLATION
ON
OFF
Turn power off. Ensure line
Use a screwdriver to remove the
1
2
voltage is compatible with
screws on both sides.
fixture.
Attach foam wall gasket to
Use a screwdriver to remove the plug of your choice for
5
6
bottom shell.
feeding wires thru. There are multiple conduit access points.
Connect the L, N, and G wires to the power supply. Connect the
8
additional ground wire (Yellow-Green).
ON
OFF
Use a screwdriver to screw on
Make sure the installation is
10
11
the screws.
complete and turn the power
back on.
Part # TWPK-1-LB4-CP3-MV-LVD
Certification # TWPK-1-LB4-CP3-MV-LVD
61505201
TWPK-2-LB4-CP3-MV-LVD
Fixture
Foam Wall Gasket
Open the fixture, push orange
3
4
connection terminal to disconnect
and release from upper cover,
and remove the upper cover from
the fixture.
Mount the back housing using screws. Ensure it is
7
leveled using the built-in bubble level.
NOTE
: Before installing the front cover:
a. Select CCT & Wattage.
b. Connect orange connection terminal.
c. Make sure gasket is aligned properly on the
fixture to ensure water seal is not compromised.
Install the cover on the hinges of the
9
fixture and connect the terminals.
STANDARD WIRE: L/live wire: Black\Brown; N/null wire: White\Blue; Ground wire: Green\Yellow-green.
TWPK-2-LB4-CP3-MV-LVD
WARNING: During grounding, make sure the earth wire of the driver and fixture housing are connected together with the earth wire of the local power supply.
SPECIAL FUNCTIONS INSTRUCTION
COLOR TEMPERATURE ADJUSTABLE INSTRUCTION
1. The color temperature of the lamp turns to 3000K when the DIP switch is set to 3K;
2. The color temperature of the lamp turns to 4000K when the DIP switch is set to 4K;
3. The color temperature of the lamp turns to 5000K when the DIP switch is set to 5K;
NOTE: Please turn off the power before adjusting the color temperature.
WATTAGE ADJUSTABLE INSTRUCTION
The power of the lamp will change to the corresponding wattage when the DIP switch is set to L/M1/M2/H.
NOTE: Please turn off the power before adjusting the wattage.
PHOTOCELL
Connecting the male and female connector will enable the photocell, Figure 1.
Disconnection the male and female connector will disable the photocell, Figure 2.
Drill through the desired
mounting hole with an electric
drill.
WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or
other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV technician for help.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
Figure 1
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com
3K 4K 5K
L M1 M2 H
Figure 2

Publicidad

loading

Resumen de contenidos para ETI Solid State Lighting TWPK-1-LB4-CP3-MV-LVD

  • Página 1 ® Order # 61505101 Part # TWPK-1-LB4-CP3-MV-LVD Certification # TWPK-1-LB4-CP3-MV-LVD STANDARD WIRE: L/live wire: Black\Brown; N/null wire: White\Blue; Ground wire: Green\Yellow-green. 61505201 TWPK-2-LB4-CP3-MV-LVD TWPK-2-LB4-CP3-MV-LVD WARNING: During grounding, make sure the earth wire of the driver and fixture housing are connected together with the earth wire of the local power supply.
  • Página 2 FIL STANDARD: L/fil sous tension: Noir\Marron; N/fil nul: Blanc\Bleu; Fil de terre:Vert\vert jaunâtre. 61505101 TWPK-1-LB4-CP3-MV-LVD TWPK-1-LB4-CP3-MV-LVD AVERTISSEMENT: Pendant la mise à la terre, assurez-vous que le fil de terre du pilote et du boîtier du luminaire sont connectés avec le fil de terre de l’alimentation électrique locale.
  • Página 3 ® Pedido # 61505101 Parte # TWPK-1-LB4-CP3-MV-LVD Certificación # TWPK-1-LB4-CP3-MV-LVD ALAMBRE ESTÁNDAR: L/cable vivo: negro\marrón; N/cable nulo: Blanco\Azul; Cable de tierra: Verde\Amarillo-verde. 61505201 TWPK-2-LB4-CP3-MV-LVD TWPK-2-LB4-CP3-MV-LVD ADVERTENCIA: Durante la conexión a tierra, asegúrese de que el cable de tierra del controlador y la carcasa del dispositivo estén conectados junto con el cable de tierra de la fuente de alimentación local.

Este manual también es adecuado para:

Twpk-2-lb4-cp3-mv-lvd6150510161505201