SAFETY PRECAUTIONS
-
Always disconnect the power supply
before installing or making modifications to the device.
- The fitting and handling of these devices must be carried out by
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
-
Always follow the instructions contained in this manual.
CHARACTERISTICS
( )
*
-
Hands-free monitor
(
also allows communication with a handset)
- 7" TFT colour screen.
-
Push buttons/ hidden push buttons
for access and selection of menu function.
- Monitor with simple installation (non-polarised 2 wires bus).
- User menu.
- Installer menu.
- Image and communication settings menu.
- Output auxiliary call repeater (max.50mA/12Vdc).
-
"HZ" input for calls from apartment front door
- Push button for Door release 1 and hidden push button for Door release 2.
- Notification leds.
- Configuration switches to assign the call address (1 to 128) and end of line.
- Function codes to define whether the monitor is master or slave (default: master).
SYSTEM OPERATION
( )
*
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and
the door panel
is in progress' message appears indicating that a call is being made. At this moment, the
apartment's monitors receive the call. If another apartment is called by mistake, press the button
for the correct apartment and the first call will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
view the image from slave monitors 2 or 3, press the one of the buttons (located above the raised
dots for the visually impaired) of the monitor to display the image. If the call is not answered within
45 seconds,
the door panel
LED
will turn off and the system will become free.
- To establish communication, press
the push button below
.
screen
or (you can also lift the handset)
Door panel LED
- Connection will last for 90 seconds or until
the push button below
screen
is pressed
or (hang up the handset only if communication has been established by lifting
the handset). When communication ends,
become free. If vocal synthesis is enabled, a 'Communication is finished' message will indicate that
the call is over.
-
To open door
or
of the door panel
, press the
2
1
or press the hidden push button below of icon
communication processes: one press will activate the lock release for
LED
will also turn on for
3
seconds. If vocal synthesis is enabled, a 'Door
indicated on the door panel.
- Detailed operation
and configuration
of the monitor
( )
INSTALA
TION OF THE
MONITOR
*
( ) For more information, see
( )
*
"TART 7T G2+
https://doc.golmar.es/search/manual/50121363
authorised personnel
.
.
.
LED
will turn on. If vocal synthesis is enabled, a 'Call
displayed on the screen will
be in
green
off-the-hook icon
shown
will turn off and the led
will
on-the-hook icon
shown on the
door panel
LED
will turn off and the system will
push button below of
icon
displayed on the screen
1
displayed on the screen during the call or
2
3
seconds and
the door panel
is
open' message will be
, see "TART
7T
/G2+"
monitor
user manual
user manual
(cód. 50121363)".
2
ART 7 /G2+
T
( )
DESCRIP
TION
*
A
B
C
D
E
J
K
L
J
( )
Monitor address (code) setup:
*
Dip1 Dip7:
-
Sets the monitor address (addresses to
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
color
. To
monitor code is the sum of the values of the switches set to ON.
Important:
Apartment 1 (Dip1 to ON & Dip2-Dip to OFF).
:
Apartment 2
1 8:
(Dip1 - Dip to OFF).
on the
turn on
.
Table of values
Switch number:
1 2 3 4 5
Value when ON
:1 2 4 8 16 32 64
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip
8
to
ON
ON
1
2
3
4
5
6
Not : e To define whether the monitor is master or slave, entering the corresponding "Special code":
.
"0550" Master (factory default), "0551" Slave 1, "0552" Slave 2 or "0553" Slave 3.
( )
*
For more information, see
EN
https://doc.golmar.es/search/manual/50121363
MONITOR
MONITOR
A. Handset.
F
B. Notifications icons:
Power on indicator.
Do not disturb.
Auxiliary relay activated.
C. Hidden push button indicator Leds
To access the main menu (monitor in standby), press either
G
of the 2 buttons
visually impaired (see "TART 7 /G2+" manual).
In call/ communication: press button to start or end the
communication.
H
In call/ communication: one press will activate the lock
*
release 1 for 3 seconds.
In call/ communication: a LED shows the location of each
I
of the hidden buttons.
Hidden button
The function of each button/hidden button is shown on the
pressing area
monitor screen with an icon located just above each
button (see "TART 7 /G2+" manual).
D. Raised dots for the visually impaired.
In standby:
Above the raised dots for the visually impaired
M
the buttons that access the main menu.
In call:
Above this raised dot is the "Start/End communication"
button
A
ON
1
2
3
4
5
6
7
8
Above this raised dot is the Door opening
SA
GND
E. Cable slot.
L
HZ
HZ
F. Speaker (hands-free communication mode).
SA
128
BUS
DIP 1 to 7
codes
G. 7" TFT colour screen.
GND
Monitor address
IN
HZ
DIP 8
BUS
OFF = 0
HZ
EOL resistor
ON = 1
OUT
H. Micro SD card slot (not included).Type:MicroSD Class 10
from 4Gb to 128Gb.
N
I.
Microphone (hands-free communication mode).
E
J. Wall mounting connector fixing (x4).
K. Configuration switches.
L. Installation terminals.
M. Speaker (communication with "handset").
N.
Microphone
Building / Villa (Nexa Door Panel)
1
1 8
2
).
7
7
ON
6
7
1
2
3
4
5
6
Example: 0+ 0+4+0+ 16+
0+0
Dip
8
to
OFF
ON
7
8
1
2
3
4
5
6
7
8
"TART 7T/G2+
user manual
(cód. 50121363)".
3
Door opening 1
.
New image/video.
*
:
/
located above the raised dots for the
T
T
/
are
.
"
1"
button
.
(communication with "handset").
7
8
= 20
EN

Publicidad

loading