Protection function
Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if
the temperature of the exhaust pipe is too low, the machine
will automatically enter protection status; if the temperature
of the exhaust pipe rises to a certain temperature, it can
automatically revert to normal operation.
Overflow Protection Function:
When water in the water pan exceeds the warning level, the
machine will automatically sound an alarm, and the "FULL"
indicator light will flash. At this point, you need to move the
drainage pipe connecting the machine or the water outlet to
sewer or other drainage area to empty the water (details see
Drainage Instructions at the end of this chapter). After the
water is emptied, the machine will automatically return to the
original state.
Automatic Defrosting (cooling models have this function): The
machine has automatic defrosting function. Defrosting can be
achieved through four - way valve reversing.
INSTALLATION AND ADJUSTMENT
1.Installation
Warning: before using the portable air conditioning, keep it
upright for at least two hours.
The air conditioning can be easily moved in the room. In the
moving process, ensure that the air conditioning is in the
upright position and the air conditioning should be placed on
a flat surface. Do not install and use the air conditioning in the
bathroom or other humid environments.