Descargar Imprimir esta página

Urmet Yokis MTV150EBRP Instrucciones De Instalación página 11

Control de atenuación conectado para control de luz 1 módulo

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
8) Minimum brightness level: The minimum brightness level may be recalled at any time by means of 4 presses.
To configure the minimum required level:
- Set the chosen brightness by holding the pushbutton pressed
- Then press 27 times: the module will flash 7 times to confirm.
- Press 28 times to restore the default setting (reply: 8 flashes).
9) 12 hour time: Temporary operation for 12 hours can be forced. Press 6 times to do this. This function may be usedful in
case of timing set to an excessively short setting for an activity.
10) Storage in case of blackout: The brightness state will be stored in case of blackout and re-established when power is
restored: the light will remain off if the dimmer was off. Otherwise, the light will return to the stored brightness. Function enabled
by default. Press 35 times to activate or deactivate the function (reply: 5 flashes).
11) Flashing mode: This function may be useful to alert hearing impaired users: the MTV150EBRP will flash for 30 seconds
when a flash command is received from the transmitter. Press any pushbutton on the transmitter to stop the flashing. Press 22
times to activate or deactivate the function. Additionally press any button on the transmitter 10 times (Configuration Menu). The
transmitter LED will flash rapidly. Then press the chosen pushbutton 19 times.
12) Use with energy-saving or LED light: The brightness must be set to a higher level if the light flickers when it is dimmed
(see point 8). Accessory SMARTCHR may be connected in parallel between light bulb return and neutral to suppress or
attenuate flickering.
WARNING: Check that the light comes on at the minimum brightness level.
Otherwise, increase the minimum brightness level (see point 8).
Multiple MTV150EBRP modules may be used to increase the total switched power. Each module must control a maximum load
of 150 W in specific manner. The modules can then be connected in wireless mode: all the dimmers will work at the same time
in this manner.
To connect two or more MTV150EBRP modules in wireless mode:
- Press the 'connect' tab on a MTV150EBRP 4 times.
- Then press the tap of the other MTV150EBRP once (1 press).
- Hold the tab of all the MTV150EBRP modules pressed for 4 seconds to cancel the connection.
CENTRALISATION
(1) Short presses sequence on pushbutton.
(2) Confirmation reply with flashes at end of press sequence.
(3) To switch the function on and off alternatively (activation
and deactivation switch).
(4) The time may be set in minutes (default) or in seconds.
P11
DS1054-076

Publicidad

loading

Este manual también es adecuado para:

5454813