13.5.2
Avoiding radio interference
The device can cause the occurrence of interference in radios, televisions or similar
devices.
Such faults can be rectified or reduced as a result of employing the following measures:
• Clean the door and the sealing surfaces of the device.
• Set the radio, the television, etc as far as possible away from the device.
• Connect the device to a different electrical outlet, so that various power circuits are used
for the device and the receiver with the interference.
• Use a properly installed antenna for the receiver, to ensure good reception.
13.6 Electrical connection
DANGER
►
Risk of electrocution
►
Touching internal compponents may cause serious, severe and fatal injuries.
►
Do not disassemble the appliance.
►
Improper grounding can cause electrical shocks. Do not use a power outlet if it is not
properly installed and grounded.
In order to ensure the safe and trouble-free operation of the device, the following
instructions must be observed for the electrical connection:
• Before connecting the device, compare the connection data (voltage and frequency) on
the rating plate with those of your electrical network. This data must agree in order that
no damages occur in the device. If in doubt, ask your qualified electrician.
• The electrical outlet must be protected by a 16A safety cut-out switch, separately from
other electricity consumers,
• The connection between the device and the electrical network may employ a 3 meter
long (max.) extension cable with a cross-section of 1.5 mm². The use of multiple plugs
or gangs is prohibited because of the danger of fire that is involved with this.
• Make sure that the power cable is undamaged and has not been installed under the
oven or over hot or sharp surfaces.
• This appliance must be electrically grounded. In case of a short circuit grounding will
protect against electric shocks because the electrical current is diverted through the
grounding lead. The appliance is fitted with an appropriate cable with a ground lead
and a grounded safety plug. The plug must be inserted into a properly installed and
grounded outlet.
• The device has to be grounded additionally for potential equalization, as usual in
commercial kitchens. If in doubt, ask your qualified electrician.
caso C1800M / C2100M