Connection example of 2 doors
Electromagnetic Lock 12V/600mA max
Adjust the output to 14.2 Vdc,
using screwdriver
See user manual
12V battery
This product herewith complies with requirements of EMC directive 2014/30/EU.
In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
Diode
1N4001
Door contact
Dip Switch
OFF
ON
1
Lan
Autonomous
2
Master
Slave
Run Led
Reader
Address 0
Push button
www.xprgroup.com
Box Tamper
Led Comm
Door contact
Example:
emergency button
Net
1. The readers for Door 1.0 must be at address 0 and those for Door 1.1 at address 1.
2. For doors equipped with 2 readers, one must be at address 0 and the other at address 1.
3. The function of OUT1, OUT2 and OUT3 can be configured in the software
4. In1 & In2: Connect to GND by a volt-free contact to activate the input
5. LIYCY cable, twisted pair, up to 80m.
If more than 80 m. are needed, then termination resistors(120 ohm) may be required at both ends of
the RS-485 line,
while taking into consideration the lengths proposed on our web site.
6. Alarm cable 2x0,22
7. The cross section of the cable depends on the current needed by the lock
Note: The elevators relay boards (WS4-RB-12) are connected on the same RS-485 lines as the readers.
electric strike
12V/600mA max
Push button
Reader
Address 1