WS4-2D-E
2-Door access control unit with web access
QUICK USER GUIDE
1. DESCRIPTION
WS4-2D-E is a 2-door control unit designed to operate over readers with RS-485 line.
WS4 is a completely autonomous device, operating without additional software or hardware.
Any device with web browser can be used for management of the WS4 system.
2. SPECIFICATIONS
• Capacity:
2500 Users
• Events:
50,000 max.
• Doors:
2 (max. 40 doors in same network)
• Readers:
2
• Door contact inputs:
2
• Push button inputs:
2
• Auxiliary Inputs:
2 (emergency, vehicle detection)
• Auxiliary Outputs:
3 (alarm, storing alarm status, presence)
• Power supply:
15 V DC/5 A
• Supply for the readers:
250 mA each max.
• Supply for the locks:
600 mA each max.
• Relay characteristics:
2 A/48 V AC/DC
• Processor:
ARM A5 - 528 MHz
• Memory:
64 MB RAM DDR2 133 MHz
• TCP/IP connection:
10/100/1000 Base-T – HTTP or HTTPS
• Operating temperature:
0 °C to +50 °C
• Humidity:
0% to 85% (non-condensing)
• Tamper:
Yes
• Wiegand readers connection:
Yes, via Wiegand to RS-485 converter - WS4-CNV
• Elevator feature:
Yes, 2 elevators per installation, each - 24 floors
• Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
• System limits of max 40 doors and 15 controllers (1 master + 14 slaves).
• Activate AUX OUT Relay when first person enters and last person leaves (Attendance).
• Minimum password length of 8 characters.
• The WS4 automatically creates an internal backup on USB memory stick at 23:00 only
if the programming has been changed. A maximum of 15 backups are retained.
3. FIRST CONNECTION AND CONFIGURATION
DIP Switch pos. 1
Serial number
DIP Switch pos. 2
The WS4-2D-E does not have default IP address. By default is set to DHCP. There are 2
methods to connect to and configure WS4-2D-E - LAN and Standalone method.
3.1 METHOD 1
(For use in a home or business LAN network)
In this configuration, the network's DHCP server will assign an IP address to your WS4-2D-E
1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of WS4-2D-E.
3. Open a web browser and enter http://ws4 followed dash and the serial number of
the WS4-2D-E controller.
If you cannot connect, your network does not recognize the name of the
WS4-2D-E controller. In this case, go to our web site http://www.xprgroup.com/
products/ws4/ and download the tool "Device Finder".
EN
FR
IT
ES
DE
NL
"Device Finder" will enable you to find out the IP address of the WS4-2D-E controller.
Run the "Device Finder" and you will get a list of all the WS4 controllers connected in
your network, including their IP addresses, as the picture below.
Open a browser and type the IP of the WS4-
2D-E controller and you will be prompted to the
login page.
User Name: admin
Password: WS4 followed by Dash and the Seri-
al Number (e.g., WS4-110034) just like the im-
age below, all in capital letters without space.
3.2 METHOD 2
(For standalone use - without LAN network)
In this configuration, the WS4-2D-E will assign an IP address to your PC. The PC must be set to obtain IP
address automatically.
1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS4-2D-E.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login
credentials as explained above.
3.3 FACTORY RESET
To do this, take the following steps:
1. Put DIP Switch 4 (Factory reset) to ON position.
2. Wait for the blinking green LED (COMM).
3. Consecutively switch the Factory reset switch (DIP 1) 3 times in the following
combination OFF - ON - OFF within 10 seconds.
4. Next, the green LED starts blinking very fast, initializes it and the factory de-
fault is completed.
4. CHANGE PASSWORD
DIP Switch 1 allows to log into the system as an administrator if login
or password is forgotten.
1. Put DIP Switch 2 (Factory reset) to ON position.
2. Wait for the blinking green LED (COMM).
3. Consecutively switch the Factory reset switch (DIP 1) 3 times in the following combi-
nation OFF - ON - OFF within 10 seconds.
4. Next, the green LED starts blinking very fast, initializes it and the factory default is completed.
5. SYSTEM SETUP
5.1 ADDING READERS
Go to "Doors", select the reader (Fig. 2) and then select the type of the reader in the
field "Card". (Fig. 3). While offline, red LED blinks fast and buzzer beeps continuously.
Once communication is established, the red LED and the buzzer stop. Green LED
starts to blink continuously. If you want to stop the green LED, go to Settings/System
Options and select the backlight ON or OFF (not default) (Fig. 4).
Factory reset
Change
password
www.xprgroup.com
Fig. 1
Fig. 3
Fig. 5
To add 2 readers on 1 Door, select the reader (Fig. 2) and there, for "Type of Access"
select "Access with 2 readers" (Fig. 5). Access with 2 readers is only available for doors 1.0
and 2.0, provided that a single door is not already configured in 1.1 or 2.1 respectively (Fig. 6).
5.2 ADDING USERS
Go to Users (Fig. 1), select "New" (Fig. 2) and then fill the form (Name, Category, Card
Number...) (Fig. 3).
Fig. 1
Fig. 2
5.3 ADDING SLAVE CONTROLLERS
One system can have up to 15 WS4 controllers (any model) and control up to 40 doors.
One WS4-2D must be master, the others must be
slaves. The master/slave selection is made with DIP-switch 2: OFF - Master (factory
setting), ON - Slave.
Go to "Doors" and click on the link "Add a slave" (Fig. 1). Enter the serial number of the
WS4-2D-E to be added and click Search. If it finds it, the system directly adds this slave
into the installation and you can configure its doors (Fig. 2).
In case of error, a message is displayed in red.
Switch
Fig. 1
Master
Slave 1
Slave 9
DIP switch 2
DIP switch 2
DIP switch 2
OFF
ON
ON
OFF
ON
Master/
1
Slave
DIP switch 2 - ON
2
Fig. 2
Fig. 2
Fig. 4
Fig. 6
Fig. 3
EN
1
Rev. 2.01 - 14.11.2023

Publicidad

loading

Resumen de contenidos para xpr WS4-2D-E

  • Página 1 (For standalone use - without LAN network) • TCP/IP connection: 10/100/1000 Base-T – HTTP or HTTPS In this configuration, the WS4-2D-E will assign an IP address to your PC. The PC must be set to obtain IP • Operating temperature: 0 °C to +50 °C Fig.
  • Página 2 6. Connection example of 2 doors Electric strike Dip Switch 12 V/600 mA max Autonomous Master Slave Run Led Box Tamper LED COMM Push button Door contact Electromagnetic Lock 12 V/600 mA max Example: emergency button Diode Reader 1N4001 Adjust the output to 14.2 V DC, using screwdriver Door contact Reader...
  • Página 3 • Anti-sabotage : • Connexion lecteurs Wiegand : Oui, via Wiegand au convertisseur RS485 - WS4-CNV Dans cette configuration, le WS4-2D-E attribue une adresse IP à votre ordinateur. L’ordinateur doit être configuré • Fonction ascenseur : Oui, 2 ascenseurs par installation - 24 étages de sorte à obtenir les adresses IP de façon automatique.
  • Página 4 6. Exemple de connexion de 2 portes Dip Switch Gâche électrique 12 V/600 mA max Autonomous Maître Esclave Boîtier anti-sabotage Run Led LED Comm Bouton-poussoir  Contact Verrou électromagnétique 12 V/600 mA max. de porte Bouton d’urgence Diode Lecteur 1N4001 Réseau Réglez la tension à 14,2 V CC à...
  • Página 5 • Funzione ascensore: Sì, 2 ascensori per installazione, ciascuno - 24 piani In questa configurazione, WS4-2D-E assegna un indirizzo IP al PC in uso. IL PC deve essere configurato per • Interblocco, Antiritorno, contapersone, presenza, registri di sistema, rapporti in CSV l’acquisizione automatica dell’indirizzo IP.
  • Página 6 6. Esempio di connessione di 2 porte Dip Switch Lucchetto elettri- Autonomous 12 V/600 mA max Master Slave Run Led Manomissione scatola LED Comm Pulsante Contatto Blocco elettromagnetico 12 V/600 mA max porta Pulsante di emergenza Lettore Diode 1N4001 Rete Regolare l’uscita a 14,2 V cc, utilizzando un cacciavite Contatto porta...
  • Página 7 Vaya a “Puertas” y haga clic en el enlace “Agregar secundaria” (fig. 1). Introduzca el número inicializa y se completa el valor predeterminado de fábrica. de serie de la WS4-2D-E que se vaya a agregar y haga clic en Buscar. Si la encuentra, el sistema agrega directamente esta placa secundaria a la instalación y puede 4.
  • Página 8 6. Ejemplo de conexión de 2 puertas Cerradura eléctrica Interruptores DIP (fallo de cierre) 12 V/600 mA max Autonomous Caja de control manual Principal Secundaria Run LED LED Comm Botón pulsador Cerradura electromagnéti- Contacto de ca de 12 V/600 mA máx. la puerta Botón de emergencia Lector...
  • Página 9 (Einzelanwendung - ohne LAN-Netzwerk) • Speicher: 64 MB RAM DDR2 133 MHz Bei dieser Konfiguration weist der WS4-2D-E Ihrem PC eine IP-Adresse zu. Der PC muss so eingestellt sein, dass • TCP/IP-Verbindung: 10/100/1000 Base-T – HTTP oder HTTPS er die IP-Adresse automatisch erhält.
  • Página 10 6. Anwendungsbeispiel für zwei Türen Dip Switch Elektrischer Türöffner 12 V/600 mA max Autonomous Gehäusesabotage Master Slave Run Led Netzwerk Drucktaster Diode Türkontakt 1N4001 Notfallknopf Leser Elektromagnetschloss max. 12 V/600 mA Netwerk Stellen Sie mit Hilfe eines Schraubendrehers die Ausgangspannung auf 14,2 V DC ein Türkontakt Leser Adresse 1...
  • Página 11 (voor gebruik thuis of via LAN-netwerk op kantoor) • TCP/IP-verbinding: 10/100/1000 Base-T – HTTP of HTTPS In deze configuratie wijst WS4-2D-E een IP-adres toe aan uw pc. De pc moet worden ingesteld voor het • Bedrijfstemperatuur: 0 °C tot +50 °C automatisch verkrijgen van een IP-adres.
  • Página 12 6. Voorbeeld 2-deursverbinding DIP-schakelaar Elektrische deuropener 12 V/600 mA max Autonomous Master Slave Behuizing sabotageschakelaar (tamper) Run LED LED Comm Drukknop Deurcontact Elektromagnetisch slot 12 V/600 mA max. Noodstop-knop Diode Lezer 1N4001 Netwerk Stel de spanning in op 14,2 Vdc met een schroevendraaier Deurcontact Lezer Adres 1...

Este manual también es adecuado para:

Ws4-2d