TROUBLESHOOTING
Common symptoms with possible causes and solutions
After turning on the power switch, the LIVE is not powered on:
No sound when playing LIVE:
Continuous long sound:
Incorrect voice:
Wrong pitch:
Some functions do not work:
1.
Make sure the USB connection is made and the computer
is on.
2.
Make sure the power connector is firmly connected to the
power outlet.
3.
Faulty USB cable. Try another USB cable or different USB
port (rear port on the computer if possible)
1.
Check the volume settings of your sound module and
speaker system. Move the Assignable Slider on LIVE to
the right most postion.
2.
Check the MIDI connection and the audio cables on your
sound module/ computer soundcard.
3.
Make sure you have the right settings in your music
software.
1.
Check Sustain Pedal and polarity.
1.
Your sound module or software is not set properly.
Initialize or restart recording software.
1.
Adjust the Octave function of the keyboard.
2.
MIDI pitch is tuned in your software/sound module. Adjust
fine tuning or coarse tuning.
3.
Pitch bend message not returned to default, please reset.
1.
Check to make sure your split point is assigned correctly
2.
Make sure your software lets you play on multiple
channels. Also, make sure both the keyboard's and
software's channels are assigned correctly.