Installation
4.1 Mounting
4.1.1 Mounting location
X
Ensure that the mounting location satisfies the following requirements:
• Mount in a dry, dust-free indoor room.
• Mount on even surface.
• Mount upright on the wall, on concrete or on any other non-flammable
surface.
• The mounting location must be protected from unauthorized access, espe-
cially by small children.
• Distance between inverter and battery: please note that the pre-fitted cables
must not be extended.
• Minimum clearance of approx. 20 cm above and below to allow free air circu-
lation.
• Sufficient distance to the side such that the type plate remains visible in
installed condition.
4.1.2 Mounting the inverter
Mark and drill the upper holes (Ø 8 mm).
X
Insert the dowels and screw in the screws. Do not yet screw tight!
X
Hang the inverter on the two screws and mark the lower holes.
X
Remove the inverter and drill the two lower holes.
X
Insert the dowels.
X
Hang the inverter on the two upper screws and screw in the lower screws.
X
Screw all screws tight.
X
The mounting of the inverter is now complete.
Z