Descargar Imprimir esta página

JBM 54392 Manual De Instrucciones página 22

Limpiador y comprobador de inyectores

Publicidad

Idiomas disponibles

Idiomas disponibles

2.2 Control Panel
3. INSTALLATION & CONNECTION
1) Move the machine onto the workbench
after unpacking and loosen the strips on the
outlet hoses.
2) Take the adjusting bolt out from the kit and
install it to the press plate on the top of the
glass tube.
3) Take the fuel distributor from the kit and
install it on the knurled nuts and tighten them
with the pressing nut.
4) Take the power cable out from the kit and
insert it into the input socket at the bottom of
the unit.
4. FIRST USE (OR REUSE AFTER
LONG TIME STORAGE)
For the new machine, or reusing after long-ti-
me storage, the pipeline of the machine is
empty and the fuel pump is not with lubrica-
tion. When it starts to work, the fuel pressure
may be difficult to establish. Now, you should
do as following:
1) Fill enough test liquid into the tank of the
machine.
2) Connect the test adaptor to the outlet pipe
and insert it into the Fill Port.
3) Power on, select the System Function, and
then select the First Use function.
4) Run it.
5) When there have liquid out from the test
adaptor, stop it. If not stop, it'll stop automa-
tically after 30s.
6) Now it can use normally.
Note: if there have no liquid out, you can run
it again.
· 22 ·
REF.54392

Publicidad

loading