Descargar Imprimir esta página

JBM 54392 Manual De Instrucciones página 29

Limpiador y comprobador de inyectores

Publicidad

Idiomas disponibles

Idiomas disponibles

REF.54392
5) Press ENTER key to start the function, adjust
the fuel pressure by pressing < or > keys.
6) Start the engine to begin cleaning.
Connecting
a) Disconnect the fuel supply hoses (E, F) of
engine fuel system (wrap the connector when
disconnecting the connector), and then choo-
se a proper connector and connect it to the
E end.
b) Stop the other end of the disconnected end
(F) with a proper stopper, (use when the fuel
pump has the fuel return function only) or re-
move the fuse of fuel pump or disconnect the
power cable of fuel pump.
1-Injector Cleaner & Tester; 2-Engine; 3-sto-
pper; 4- Fuel-inlet hose to engine;
Tidy up after cleaning
a) After the cleaning is completed, turn off the
Ignition Switches restitute the link of the fuel
hoses then start and check the leakage of fuel
system.
b) At last please clean the fuel tank and hose
line with test liquid (if there is residual deter-
gent inside fuel tank, please.)
c) Tidy up and make preparation for the next
cleaning.
Note:
1) When cleaning, care must be taken as the
detergent  is  inflammable.  Prepare  for  a  fire 
extinguisher.
2) Be sure that all hose lines are well connec-
ted and there is no leakage on the hose lines
before performing cleaning.
7. TRANSPORTING AND STORING
7.1. Transporting
1) Before being packed, the liquid inside the
fuel tank should be drained completely to
avoid overflowing as transporting.
2) Move only by hand or lift with soft belt.
3) No package no lifting tools or long-distance
transportation.
4) To prevent the unit from shocking and knoc-
king, make sure it is on the base seat and in
the packing case during transportation. Firstly
pack the unit with the matter similar with plas-
tic strip and add the filling material (such as
foam or sponge, etc.) between the unit and
packing case to avoid scratching the surface
when the unit shakes.
5) Make sure that the maximum incline angel
does not exceed 45 . Do not place the unit up-
side-down.
7.2. Storing
1) Store only in dry area and keep away from
water before the unit is unpacked.
2) Store the machine in well-ventilated area
and do not expose it to direct sun shine or rain.
7.3 Installation Environment
1) Keep a distance of no less than 200mm be-
tween the unit and any wall or other substan-
ce. The unit should be put in well-ventilated
area. Make sure the temperature is within -10°
+40°.
2) The unit has been well grounded for safety
operation. Please confirm that the power soc-
ket is also well grounded.
Warning!
If an extension cord is used, the rated current
should be equal to or greater than that of the
equipment.
8.  TROUBLESHOOTING  &  PRECAU-
TIONS
8.1 Troubleshooting
1) The unit does not correspond when it is swit-
ched on.
Check the fuse at lower right side of the unit
and replace it (5A) if it is damaged or broken.
2) There is leakage in the fuel distributor cou-
pler. Check the O-rings and replace it if it is
damaged or unfitted. Do not tighten the two
riffle screws too tightly; otherwise, it may cause
leakage.
3) When running, there is no working pressure.
New machine is first used, or the machine has
not been used for a long time, there may be no
fuel pressure.
· 29 ·

Publicidad

loading