Air-to-water Heat Pump Monobloc Versati
Notes:
1)Two-way valve is very important to prevent dew condensation on the floor and Radiator while
cooling mode.
2) 3-Way valve 1 is controlled by user,while the pool pump is actived, 3-Way valve 1 switches to
pool loop;while the pool pump is shuted down,3-Way valve 1 switches to under floor/FCU loop.
3) 3-Way valve 2 is automatic controlled by monobloc unit,while running water heating mode,3-
Way valve 2 switches to water tank loop;while running cooling/heating mode,3-Way valve 2 switches
to under floor/FCU loop.
7 Main Components
(1) GRS-CQ8.0Pd/NaC-K,GRS-CQ10Pd/NaC-K
DC Fan Motor
Compressor
Plate Heat Exchanger
11
Control Box
Electric Heater
Water Pump
Flow Switch
Expansion Tank

Publicidad