Descargar Imprimir esta página

Pearl CQPL Serie Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para CQPL Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN MANUAL AND ON PUMP.
Before installation, you should carefully read
this manual, and pay attention to safety
cautions and instructions in this manual.
Our factory is neither responsible for nor is
reliable for paying compensation for
personal injury, pump damage and other
property losses caused by violation of safety
cautions.
1. GENERAL INFORMATION
1.1. It is applicable to household water supply, equipment
support, pipeline pressurization, garden watering, vegetable
greenhouse watering,fish farming and poultry raising, industrial
and mining, water supply and drainage of enterprises and high-
rise buildings,central air conditioner and centralized heating
circulation system, etc.
1.2. Transfer clean water and other non-corrosive liquids with
low viscosity; do not transport inflammable, explosive, gasified
liquids and liquids containing solid particles or fibers. The PH
value should be within 6.5-8.5.
2. MODEL DESCRIPTION
CQPL 05 A 1 6 S
3. TECHNICAL DATA
Max. Flow: 1800L/min
Max. Head: 75m
Output power: 0.25~11kW
Max. Suction: 8 m
Insulation grade: IP44
Protection grade: F
Max. ambient temperature: +40
Max. liquid temperature: +60
4. IMPLEMENTATION STANDARDS
IEC/EN 60335-1 Household and similar electrical appliances-
-safety Part1:General requirements.
IEC/EN 60335-2-41 Household and similar electrical
appliances--safety Part2-41:Particular requirements for pump.
2006/95/EC Low voltage directive
INSTALLATION AND OPERATING INSTRUCTIONS
Features S=Standard
Hertz 5=50hz, 6=60Hz
Phase 1=Single phase, 3=Three phase
Voltage A=115V, C=230V, F=110/220V
HPx10
Series Centrifugal Pump
centrifugal water pumps
5. SAFETY PRECAUTIONS
5.1. To ensure normal and
safety operation of the
electric pump, read manual
carefuly before use.
ON
OFF
1 1
1 1
0 0
0 0
5.3. Do not touch the
electric pump while
working; do not wash,
swim near working area
or let livestock into the
water to avoid accidents.
CQPL
l
M a n u a
5.2. The electric pump should
have reliable grounding to
prevent short circuit; for
safety, leakage protection
switch should be equipped
and be careful no to wet the
power plug; socket should be
connected in damp - proof
area.
5.4. Avoid splashing
pressured water to the
electric pump as well as
prevent the pump immersed
by water.

Publicidad

loading

Resumen de contenidos para Pearl CQPL Serie

  • Página 1 CQPL centrifugal water pumps INSTALLATION AND OPERATING INSTRUCTIONS TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP. Before installation, you should carefully read this manual, and pay attention to safety cautions and instructions in this manual.
  • Página 2 6. PRODUCT STRUCTURE 5.5. Keep the pump in ventilation. 5.6. In case ambient tempera- ture is lower than 4 or the pump is not used for a long time, empty liquid the pipeline system to avoid ice cracking of the pump chamber. Do not operate the pump for a long time without water in it.
  • Página 3 NEGATIVE SUCTION INSTALLATION PRECAUTIONS FOR INLET PIPELINES 1. While installing the electric pump, do not use too soft rubber CORRECT INSTALLATION tube for the inlet pipeline, avoiding to be sucked flat. 2. The foot valve should be vertically placed and installed 30 cm 1.
  • Página 4 SINGLE PHASE CONNECTION 110V or 220V 9. START-UP MAINTENANCE Do not start up the pump before the pump chamber is filled with water. CAPACITOR Do not touch the electric pump unless its power has been cut off for at least 5 minutes. Do not dismount the pump body unless water in the pump chamber is empted.
  • Página 5 10.TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Single-phase power supply (three-phase electric motor): a. repair switch contact or replace the switch; a. poor connection of the power switch; b. replace the safety fuse; b. fuse is burned out; c. check and tighten the power connector; c.
  • Página 6 bombas de agua centrifugas MANUAL DE INSTALACIÓN Y MANTENIMIENTO Antes de la instalación, lea cuidadosamente este manual y ponga atención a las medidas de seguridad e instrucciones de este manual. Nuestra empresa no responde ni paga compensaciones por daños personales, daños a la bomba u otras pérdidas causadas por la violación de las medidas de seguridad.
  • Página 7 6. PARTES 5.4 Se debe evitar lavar la electrobomba con agua a presión, así mismo se debe prevenir que el equipo se inunde. 5.5 Mantenga la bomba en un lugar ventilado 5.6 En caso que la temperatura POS. PART ambiente este por debajo de 4°C ó...
  • Página 8 SUCCIÓN NEGATIVA PRECAUCIONES DE INTALACIÓN EN LA SUCCIÓN INSTALACION CORRECTA 1. No use demasiado pegante de PVC o cinta teflón en las uniones roscadas, para evitar que los sobrantes obstruyan la 1. Válvula de pie 2. Tubería de succión tubería. 3.
  • Página 9 CONEXIÓN TRIFÁSICA 8.2 EN LO POSIBLE EVITE QUE LA ELECTROBOMBA QUEDE MUY LEJOS DE LA FUENTE DE SUMINISTRO ELÉCTRICO. En la medida que esta fuente este a mayor distancia de la bomba el cable debe ser de mayor calibre, de lo contrario el voltaje se baja y la electrobomba trabaja de manera anormal llegando incluso a dañarse severamente.
  • Página 10 3. En caso que la electrobomba no se vaya a usar por largo 9.5 El registro debe estar totalmente cerrado antes de arrancar tiempo, vacié el agua de la bomba, recubra el cuerpo de la la bomba. bomba, el impulsor y el plato porta sello con aceite anticor- rosivo.