Descargar Imprimir esta página

Modular EM 70/40 GRL Serie Instalación, Uso, Mantenimiento página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Position the "A1" type appliance below an
extractor hood to ensure smoke and fumes
generated by cooking are removed.
"B21" TYPE APPLIANCE
Position the "B21" type appliance below an
extractor hood.
"B11" TYPE APPLIANCE
Fit the "B11" type appliance with a suitable fl ue,
available from the appliance manufacturer. Follow
the assembly instructions provided with the flue.
Connect the flue to a 150/155 mm diameter hose,
heat resistant to 300°C.
Vent to the outside or into an efficient fl ue.The
hose length must not exceed 3 metres.
6. CONNECTIONS
The position and dimensions of connections are
given in the installation diagram at the end of this
manual.
CONNECTION TO THE GAS SUPPLY
- Check that the appliance is designed to operate
with the type of gas supply present on site. Check
the information given on the decals on the packing
and appliance.
- Convert the appliance to the local gas type, if
necessary. Follow the instructions at the next
paragraph "Conversion to a different type of gas".
- On top appliances a rear connection is also
available. Remove the plug present and screw it
tightly onto the front connector.
- A rapid-action gas shut-off valve must be fitted
upstream of the appliance in an easily accessible
position.
- Do not use connection pipes having a diameter
smaller than that of the appliance's gas connector.
- Once the appliance has been installed, check for
gas leaks at the connection points.
ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at
the voltage and frequency of the power supply
present on site. Check the details given on the
appliance dataplate.
- Install upstream of the equipment in an easily
accessible place, an all-pole disconnecting device
with a contact gap of allowing full disconnection
under the conditions of overvoltage category III.
- A
flexible
rubber
specifications not lower than type H05 RN-F must
cable
with
insulation
be used for connection.
- Connect the power supply cable to the terminal
board as shown in the wiring diagram supplied with
the appliance.
- Secure the power supply cable with the cable
clamp.
- Protect the power supply cable on the outside of
the appliance with a rigid plastic or metal pipe.
PROTECTIVE EARTH AND EARTH BONDING
CONNECTIONS
- Connect the appliance to an efficient ground
circuit. Connect the earth conductor to the
terminal with the symbol
terminal board.
- Connect the metal structure of the appliance to the
equipotential node. Connect the conductor to the
terminal with the symbol on the outside part of
the bottom.
CONNECTION TO THE WATER SUPPLY
- The appliance must be connected to a potable
water supply. The water inlet pressure must be
between 150 kPa and 300 kPa. Use a pressure
reducer if the inlet pressure is above the maximum
permitted level.
- Install a mechanical filter and a shut-off valve
upstream of the appliance in an easily accessible
point.
- Make sure the water circuit is free of ferrous
particles before connecting the filter and the
appliance.
- Seal any unused connectors with a plug.
- Once the appliance has been installed, check for
gas leaks at the connection points.
CONNECTION TO THE WATER DRAIN
The water drainage system must be made using
materials resistant to temperatures of 100 °C.The
bottom of the appliance must not be subjected to
steam produced by drainage of hot water.
Install a siphoned floor drain with grating below the
water drain cock of Boiling pans and in front of
Bratt pans.
7. CONVERSION TO ANOTHER
Table Tab1 specifies:
which gas can be used for the appliance.
18
next to the main
TYPE OF GAS

Publicidad