Descargar Imprimir esta página

Beamz LED PAR36 DMX SPOT Manual De Instrucciones página 6

Ocultar thumbs Ver también para LED PAR36 DMX SPOT:

Publicidad

Idiomas disponibles

Idiomas disponibles

Settings and operation
Press "Menu" to switch to the Menu.
Slave setting
When display shows "SLAv" it's in slave mode
Factory value setting
When display shows "LoAd" press "ENTER" to set the unit back into factory settings.
DMX functions:
Channel DMX Value
1
0 - 255
2
0 - 255
3
0 - 255
4
0 - 255
5
0 - 255
6
0 - 255
0 – 255
7
0 – 29
8
30- 74
75 - 119
120 – 164
165 – 209
210 - 255
A DMX signal terminator is recommended to avoid a bad signal caused by other electrical devices. A DMX terminator is a
XLR connector with a 120Ω resistor between pin 2 and pin 3 of the XLR connector. Connect it to the last OUTPUT socket
of the final light.
See picture:
IN
OUT
All manuals and user guides at all-guides.com
DMX address setting.
When display shows "A001" you can set the DMX address.
Press "UP" or "Down" to adjust the value (001 – 512), press "ENTER" to
save the address setting.
Work mode setting.
Axxx = DMX control
ATxx = Auto/Sound mode
Edxx = Auto mode
Slav = Slave mode
Load = Reset to factory defaults
Press "UP" and "DOWN" button to adjust, press "ENTER" to save.
Function
Dimmer
White LED Group 1
White LED Group 2
White LED Group 3
Strobe (slow-fast)
Changing gradually (slow-fast)
Changing sharply (slow-fast)
DMX channels, channels from CH1 to CH7 are controlled by DMX
Automatic mode
Sound control mode 1
Sound control mode 2
Sound control mode 3
Sound control mode 4
IN
- 5 -
OUT
IN
OUT
120Ω

Publicidad

loading

Este manual también es adecuado para:

151.264