8. Electrical connections
64
Module output description
Description of the outputs of the ecoMAX 860P3- v. O module and the expansion
module ecoMAX 800 S2- B module
Moduł A
STB- thermal safety device
EF- hopper feeder
CF- burner fan
IF- burner feeder
IG- igniter
BP- boiler pump
HWD - DHW pump
AC- ash removal engine (not applicable for this boiler version)
BC- cleaning engine (not applicable for this boiler version)
GC - grate actuator
PM A - CH mixing valve pump - circuit A
SM A - mixing valve - circuit A
GCS - cleaning actuator control signal
λ, B - module input
OS - flame sensor
FL - cleaning actuator feedback
RMP - fan
PLS - minimum fuel level sensor
H- universal entrance
DS - door limit switch
RP - room temperature controller
BP - boiler control panel
BT - boiler temperature sensor
FS - burner temperature sensor
WS - external sensor
CWU - DHW sensor
RS - return temperature sensor
AS - ash pan limit switch
M A - CH sensor - circuit A
T A- CH room temperature controller - circuit A
Leader in pellet boilers
Module B
MC - CH sensor - circuit C
MD - CH sensor - circuit D
BH- upper boiler temperature sensor
BL - lower boiler temperature sensor
T C - CH room temperature controller - circuit C
T D - CH room temperature controller - circuit D
H2- control output for backup boiler, alarm signalling, or hot water pump
HWP- hot water pump
PM C- CH pump - circuit C
SM C - CH mixing valve - circuit C
PM D - CH pump - circuit D
SM D - CH mixing valve - circuit D