ELECTRICAL GROUNDING INSTRUCTIONS: (continued)
DUTY CYCLE:
To ensure long life of your BOSTITCH air compressor, do not operate on more than a 50% duty
cycle. If this air compressor pumps air more than 50% of one hour, then the compressor's
capability is less than the air delivery required by the application. Always match the air
volume requirements of the attachment or accessory with the air volume delivery of the
compressor.
Notice!: BOSTITCH does not recommend the use of extension cords with compressors. The
use of an extension cord can result in the loss of voltage supplied to the compressor which
could prevent the compressor from starting. For optimum performance, plug the compressor
directly into an outlet and increase the length of airline as needed.
If an extension cord must be used, use these guidelines:
CAP2060P/CAP2060PC
Motor:
Fuse Requirements:
Operating Pressure:
Safety Valve Setting:
Displacement:
Air Delivery:
Maximum Amps at Working Pressure:
Tank Size:
Air Outlet:
Pressure Switch Settings:
Weight:
PSI = Pounds Per Square Inch:
Distance Needed
Less than 25 ft.
25 - 50 ft.
Greater than 50 ft.
Recommended Gauge
12 Gauge
10 Gauge
Not Recommended
6
SPECIFICATIONS
2HP (Peak) / 1.6HP (Running)
115V – 60HZ
15 Amps minimum
0 – 125 PSI
140 PSI
3.4 CFM @ 40 PSI
2.7 CFM @ 90 PSI
10.5
6 Gallons
1/4" NPT
On @ 95 PSI
Off @ 125 PSI
51lbs.
CFM = Cubic Feet Per Minute