Descargar Imprimir esta página

Franke PAC 5 GAV-MTC Instrucciones Para El Uso E Instalacion página 17

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Electrical connection
Your FRANKE hob comes equipped with a 3-pole power cable with free terminals.
If the hob is connected permanently to the power supply, fit a circuit breaker having a contact opening
distance that allows complete disconnection in overvoltage category III. Make sure that:
a) the plug and the mains socket are suited to a 16 A current;
b) they are both easily accessible and positioned so that no electrical part can be accessed when inserting or
unplugging the same plug;
c) the plug can be inserted without difficulty;
d) the plugged in and fitted oven is not resting on the plug;
e) do not connect the terminals of two appliances to a single plug
f) if the power cable needs to be replaced use a 3 x 1.5 mm
g
it is vitally important to observe the polarities of the free terminals
)
(Brown=Live – Blue=Neutral – YellowGreen=Earth).
N.B: ensure the characteristics of your domestic electrical power supply (voltage,
maximum output and current), are compatible with those of your FRANKE hob.
Replacing injectors
Warning. All appliances are factory-set for G20 natural gas (methane).
In the event a different type of gas is to be used, change the injectors as follows:
1. remove the panstand grids, burner caps and flame-spreader crowns;
2. unscrew and remove the injectors and replace them with those supplied suitable for the domestic gas
supply, ensuring that the injector marking corresponds to that given in the table (page 14);
3. replace the flame-spreader crowns, burner caps and panstand grids;
4. these particular burners do not require any air adjustment.
Warning
When converting the appliance to a different type of gas, remember to apply the self-adhesive label
(supplied with accessories) indicating the type of gas used in the relevant section on the dataplate. For operation
with L.P .G. (G30 or G31) fully screw down the minimum flame setting screw. This is a cat. II 2H3+ appliance.
Adjusting the minimum setting
- Remove the control knobs (which have a push-on design for ease of
removal).
- Ignite the burners and adjust the minimum setting by turning the
adjustment screw clockwise to reduce the flame and anti-clockwise to
increase it (fig. 3). The screwdriver for carrying out this adjustment is
supplied with the other accessories.
2
cable type H05VV-F ,
Lowest
minimum
setting
BLUE
YELLOW-GREEN
BROWN
Highest
minimum setting
Fig. 3
13

Publicidad

loading