deviations of each path built immediately after reaveraging several times will be within a
few centimeters. Take a look on the right of figure 4.
If the baseline is too long to obtain FIX, averaging float solution will still improve the
position to 1m level.
Perfect for data collection and surveying, placing GCPs, and drone mapping: The base
position averaged using FIX solution provides several centimeters accuracy and works great when
you need accurate absolute position!
2.7.5. Post-Processed Kinematics
With Static processing, you may determine base coordinates without real-time corrections
with centimeter accuracy. You will need RINEX logs from the reference station in the area of
100 km and the raw data log from the receiver.
General steps:
1. Enable logging of raw data and record log for about an hour.
2. Export log with the collected data from Emlid Flow to your PC.
3. Refer to the PPK in Static mode tutorial.
4. After you get the coordinates you may enter them manually in the Base coordinates
section.
Comparing the position obtained using Static processing to the averaged
position and applying corrections to the collected data is the way to compensate
the shift shown in the example in Figure 2.