Operation
1.
Press the start button
to turn on the nebulizer.
The nebulizer is now in STANDBY mode and the LED is lit red;
and
keys to select and set the frequency, duration of the cycles or engine
2.
Use the
power level;
3.
Press the
key: the nebulizer is now in SETTING mode. The frequency, duration or clock
value will flash for 8 seconds; after 8 seconds the nebulizer will return to STANDBY mode
and save the selected value;
4.
Within the 8 seconds mentioned above, start to select the desired value using
the keys
and
:
or
key will display the values one after the other, in ascending or
A. Pressing the
descending order;
B. Press and hold the
or
and continuously;
5.
After selecting a value:
A. press the Play key
to save the selection and go directly to
the next selection (frequency, duration of the cycles or engine power level);
key to exit without saving and return directly to SETTING mode for
B. press the
the next selection (duration or interval);
6.
The value to be selected will flash for 8 seconds: within this time, use the
start selection:
A. press the Play key
to save the selection;
B. press the
key to exit without saving and return directly to the SETTING mode
for the next selection (frequency, duration of the cycles or engine power level);
74
Art. 432
Geyser Nebulizer E-25 MI 21 V
Assembly and use
key makes the display show the selectable values faster
and
Art. 432
Geyser Nebulizer E-25 MI 21 V
Assembly and use
7.
Press the Play key
seconds to ensure the safety of the operator, who has time to move away from the device.
During these 30 seconds the LED lights up green and flashes and the nebulizer emits
repeated beeps.
During these 30 seconds, the nebulizer mixes the liquids through an internal nozzle located
on the bottom of the tank. Mixing always takes place using the maximum power of the
engine (PWR 03). At the end of the mixing, the nebulizer will work with the power value
(PWR) previously set.
8.
Once the operation has been carried out for the set duration, the nebulizer returns to
STANDBY mode and will automatically start after the selected time interval has elapsed.
The nebulizer prevents starting of a new cycle when the battery charge level is less than
25% (one bar). Recharge the battery.
If the tank is empty, the nebulizer returns to STANDBY mode with the red LED and
flashing.
The current selection and the clock is saved every time the nebulizer is turned off. This
means that, after turning the nebulizer on again, the user can simply press the Play key
to continue using the same settings as before for spraying.