Maintenance and care
Lubricating flexible shaft
Angle transmission
Method to change shield
All the surface of the flexible shaft should always be properly
greased.
At the time of delivery from the plant, this is greased, so evenly
grease all the surface of the flexible shaft approximately 10 mL
in every 18 hours.
IMPORTANT
Use genuine Urea based grease (Part number: X695-000070)
whose dropping point is 250
um based grease.
1.
Draw out the flexible shaft assembly from the engine.
2.
Draw out the flexible shaft from the flexible shaft assembly.
3.
Use the Urea based grease.
4.
When reassemble, it is preferable to fit the flexible shaft re-
versely.
1.
Remove the plug (A) and drain screw (B) from the angle
transmission (C).
2.
Add Lithium or Urea based grease into the transmission until
old grease is pushed out. If necessary, use a low pressure
pump.
3.
Reinstall the drain screw and plug.
There are two types of shields: namely the one used exclu-
sively for nylon line cutting head and the other one used exclu-
sively for metal blade. When metal blade is used, use the
shield for metal blade.
1.
Fully loosen the bolt (A) on the right side of the bracket (B)
to slide the shield. The bolt itself cannot be removed from the
bracket.
2.
Pushing the button (C), slide the shield (D) to the left and re-
move it.
3.
Put shield of other type (E) into groove and slide it to the right
until it stops. Be sure to tighten the bolt.
24
o