If connecting leads and electric animal fence
wires are installed near an overhead power line,
their height above the ground shall not exceed
3 m (10'). This height applies to either side of
the orthogonal projection of the outermost
conductors of the power line on the ground
surface, for a distance of:
2 m (6'6") for power lines operating at a
nominal voltage not exceeding 1000 V.
15 m (50') for power lines operating at a
nominal voltage exceeding 1000 V.
Electric animal fences intended for deterring
birds, household pet containment or training
animals such as cows need only be supplied
from low output energizers to obtain
satisfactory and safe performance.
In electric animal fences intended for deterring
birds from roosting on buildings, no electric
fence wire shall be connected to the energizer
earth electrode. A warning sign shall be fitted
to every point where persons may gain ready
access to the conductors.
Where an electric animal fence crosses a public
pathway, a non-electrified gate shall be
incorporated in the electric animal fence at that
point or a crossing by means of stiles shall be
provided. At any such crossing, the adjacent
electrified wires shall carry warning signs.
Any part of an electric animal fence that is
installed along a public road or pathway shall
be identified at frequent intervals by warning
signs securely fastened to the fence posts or
firmly clamped to the fence wires.
The size of the warning sign shall be at
least 100x200 mm (4x8").
The background colour of both sides of
the warning sign shall be yellow. The
inscription on the sign shall be black and
shall be either:
or the substance of "CAUTION: Electric
fence".
The inscription shall be indelible, inscribed
on both sides of the warning sign and
have a height of at least 25 mm (1").
Ensure that all mains-operated, ancillary
equipment connected to the electric animal
fence circuit provides a degree of isolation
between the fence circuit and the supply mains
equivalent to that provided by the energizer.
Protection from the weather shall be provided
for the ancillary equipment unless this
equipment is certified by the manufacturer as
being suitable for use outdoors, and is of a type
with a minimum degree of protection IPX4.
Important safety instructions for
Class 2 power units (USA/Canada
only)
When using electrical products, basic
precautions should always be practiced
including the following:
1
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
2
Read and follow all instructions that are
on the product or provided with the
product.
3
Do not use an extension cord.
4
Reference the National Electrical Code,
ANSI/NFPA 70, specifically for the
installation of wiring and clearances from
power and lighting conductors.
5
Installation work and electrical wiring
must be done by qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated
construction.
6
Do not install or use within 3 m (10') of a
pool.
7
Do not use in a bathroom.
8
WARNING: Risk of Electric Shock. When
used outdoors, install only to a covered
Class A GFCI protected receptacle that is
weatherproof with the power adaptor
connected to the receptacle. If one is not