Installing The Transformer; Connection Of An Electric Catch, Lock Or Of A Gate Motor; Technical Specifications; Power Supply - Extel WEPA 241 Instrucciones De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
c. Installing the transformer (

-
A ttach the transformer to a DIN rail in a modular fusebox or to a flat surface using the two black lugs clipped
to the sides of the transformer. (fig. 4c).
SAFETy INSTRUCTIONS
The transformer must be mounted to a DIN rail in a modular fusebox or surface-mounted on a non-metal
surface using the two mounting holes. The terminal block covers must be fitted. The unit should be connected
to an electrical installation meeting applicable standards (NFC 15-100 for France) AFTER WIRING IS COM-
PLETELy FINIShED.
Protection : The transformer is fitted with a thermal cut-out. If a fault or short-circuit occurs the following
steps should be taken to restore transformer protection.
1. Disconnect the 230 V~ power supply (for at least 2 minutes).
2. Repair as needed.
3. Reconnect the 230 V~ power supply.
WIrING
4
See the wiring diagram (fig. 5 for WEPA241 or fig.6 for WEPA242).
Wires to be used for WEPA 241 :
Wires to be used for WEPA 242 :
a. Connection of an electric catch, lock or of a gate motor
An electric lock or strike may be connected to terminals 9 and 10 on the roadside panel. To control an automatic
gate opener, connect the optional WE 8111 BIS unit between terminals 9 and 10 and the two «external control»
terminals on the automatic opener.
The strike, lock or automatic opener will be controlled by the
b. Connecting an optional extra WEPACB 243 indoor station
An additional WEPACB 243 handset may be connected in parallel with the main handset (fig. 7).
- Intercom between the two handsets (optional WEPACB 243) : The
cond handset and communicate discreetly. (Calls from the roadside panel are disabled while using the intercom
function)
5

TECHNICAl sPECIfICATIoNs

a. Indoor unit
(PACB 241 or PACB 242)
• Reference: 810243
• Power supply: 12V~
• Consumption: 12W
• Dimensions (mm): 210x70x40
b. Power supply
• Reference : 830241
• Tension : 230V~/12V~
If the power supply cable is cut, check the polarity
3GB
fig. 4c)
• 2 wires 6 /10 mm up to 25 m
• 4 wires 6 /10 mm up to 25 m
18VA
CFI EXTEL WEPA 241/242 - 09/2010 - V1
• 2 wires 1.5 mm
• 4 wires 1.5 mm
(fig. 5 ou 6)
button on the handset(s).
button can be used to call the se-
up to 100 m
2
up to 100 m
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wepa 242

Tabla de contenido