SYSTEM UPDATING
To carry out the device update, you need to download the firmware on
theproduct page of the Comelit Professional website.
The firmware consists of two different files:
The file called "monitor" must be copied onto a uSD card and inserted
into the device.
The second "bracket" file must be applied using the Safe Manager
configuration software (same firmware update procedure as for the
control panel and/or peripherals).
Update procedure for "monitor" via uSD card
Once the firmware has been downloaded from the website, it must be
copied into the uSD card (FAT32, max. 32GB) memory which should then
be inserted into the top of the product.
uSD card
While the device is off, insert the uSD card and only after doing so, switch
on the VEDO5TPR / VEDO5TPRW.
If a valid file is detected, the system will automatically update the firmware
after confirmation is given.
SD Card is detected.
Do you want to start
firmware upgrade?
Yes
No
At the end of the process you will need to restart the device and remove
the uSD card.
Update procedure for "bracket" using Safe Manager software.
Use the function "Tools -> Updating firmware -> peripherals" in the Safe
Manager configuration software to transfer the file using the control panel
and proceed with the device update.
12