To Change the Ribbon
Note:
The ribbon cartridge does not come installed. Use the following instructions to install the
cartridge before using the Simplex 125.
To Remove the Ribbon Cartridge
1.
Unlock and remove the cover.
2.
Grasp the ribbon cartridge by its tab and pull it straight out the side of the Simplex 125.
To Install the Ribbon Cartridge
1.
Unpack a ribbon cartridge.
2.
Rotate the knob on the ribbon cartridge
clockwise to remove all ribbon slack.
3.
Slide the cartridge's exposed ribbon under
the print head. Then snap the ribbon car-
tridge into place while ensuring that the rib-
bon is fully seated.
4.
Temporarily apply power to the clock
(refer to the section "To Connect Power"
on page 6) to take a test print on a clean
sheet of paper.
• Ensure that the imprint is complete and
smudge-free.
To Set the Print Margin
Note:
Set the Print Margin before wall mounting the Simplex 125.
1.
Using a piece of paper, determine where you want the leading edge of
the imprint placed with respect to the card/document edge.
2.
Set the trigger stop (located under the base of the clock) to the desired
depth.
3.
Temporarily apply power to the clock (refer to the section "To Con-
nect Power" on page 6) to test the Print Margin.