Descargar Imprimir esta página

Craftsman 919.152144 Manual Del Propietário página 18

Ocultar thumbs Ver también para 919.152144:

Publicidad

Idiomas disponibles

Idiomas disponibles

Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance"
section on the preceding
pages and perform scheduled
maintenance as necessary.
2.
Set the On/Auto/Off lever to
"OFF" and unplug unit.
3.
Turn the regulator
counterclockwise and set the
outlet pressure to zero.
4.
Remove the air tool or accessory.
5.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
6.
Drain water from air tank by
opening drain valve on bottom of
tank.
A13566
STORAGE
condense in the air tank. If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
7.
After the water has been drained,
close the drain or drain valve.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, then
reinstalled.
8.
Protect the electrical cord and
air hose from damage (such as
being stepped on or run over).
Wind them loosely around
the compressor handle. (If so
equipped)
9.
Store the air compressor in a
clean and dry location.
18- ENG
Risk of Bursting.
Water will

Publicidad

loading