4.3 POSITIONING
• For correct operation of the heater, install it in a vertical position.
• Use the mounting template included in the package. As an example, see template model 11 l / min:
• The fastening elements are in the bag of accessories included in the water heater packaging (wall plugs for fixing upper and
lower fixing screws)
• Hang the water heater of hooks and tighten the screws to attach it to the wall.
• Connect the flexible hot and cold water hoses without forgetting to check for leaks. Do not remove the filter at the cold water
inlet in order to avoid circulation problems.
Ø6
110
110
220
328
220
110
110
2
1
3
cod. 30902370 - Rev. 01 - 11/2017
1. Hot water outlet
2. Gas inlet
3. Cold water inlet
5
15
1. Hot water outlet
2. Gas inlet
3. Cold water inlet