Montaje en panel de interruptor de circulo por falla a tierra autoverificación portátil

Publicidad

Enlaces rápidos

WARNINGS:
• TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE AND TEST THAT THE POWER IS OFF
BEFORE WIRING!
• To be installed and/or used in accordance with appropriate electrical codes
and regulations.
• If you are not sure about any part of these instructions, consult
an electrician.
• This device is not to be used, directly or indirectly, with a life-support
apparatus or associated circuitry. Use this device only on a grounded
circuit, protected by a fuse or a circuit breaker.
TO INSTALL
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS
OFF BEFORE WIRING!
2. Mount Self-Test GFCI panel securely with screws and nuts
Torque each screw 17in-lbs. DO NOT OVER-TIGHTEN.
3. Connect wires per Wiring Diagram as follows:
a) BLACK lead to LINE (Hot); WHITE lead to LINE (Neutral). Twist
strands of each lead tightly and, with circuit conductors, push firmly
into the appropriate wire connector. Screw connector on clockwise,
making sure that no bare wire shows below the connector.
b) If connecting to circuit breaker, securely connect LINE BLACK wire
(Hot) to designated circuit breaker and connect LINE WHITE wire
(Neutral) to bus bar.
4. Follow wiring instructions for receptacle to securely terminate LOAD
WHITE wire to Neutral screw or lead of receptacle.
5. Follow wiring instructions for receptacle to securely terminate LOAD
BLACK wire to Phase/Hot screw of receptacle.
6. Restore power at circuit breaker or fuse.
7. See LED color chart below for status.
LED COLOR CHART
COLOR
NO POWER
POWER
GREEN
OFF
RED
OFF
TEST INSTRUCTIONS FOR GFCI
1. Turn on Power. GREEN power light goes ON. If the fault status RED
indicator light turns on or continuously blinks RED, or if the GFCI cannot
reset, refer to the Self-Test Operation section.
2. Press TEST/RESET button and release. Power light must go OFF.
3. Press TEST/RESET button and release. Power light must go ON for use.
CAUTION: DO NOT USE THIS DEVICE IF ABOVE TEST FAILS. TEST
UNIT BEFORE EACH USE. DO NOT TEST THIS UNIT WITH THE
CONNECTED LOAD IN THE "ON" POSITION.
SELF-TEST OPERATION
A Self-Test GFCI has all the features of a conventional GFCI panel mount. In
addition, this panel tests itself periodically to confirm that the GFCI electron-
ics are functional. The LOAD indicator light will be solid GREEN when the
GFCI is powered from the LINE side and working correctly.
Self-Test Indications: If the fault indicator light is solid or continuously
flashing RED, a problem may exist. Press the TEST/RESET button to trip the
GFCI. If unable to reset, replace the GFCI.
NOTE: The fault indicator may flash RED at power "ON" and reset.
Patents covering this product, if any, can be found on Leviton.com/patents.
SmartlockPro
®
is a trademark of Leviton Manufacturing Co., Inc., registered
in the United States, Canada, Mexico, and China.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
IC STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the
Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in
materials and workmanship under normal and proper use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair or
replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal
of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or
altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties
of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of
any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect,
special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to
perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com.
SmartlockPro
Fault Circuit Interrupter Panel Mount
INSTALLATION INSTRUCTIONS
provided.
FAULT
DETECTION
ON
OFF
OFF
ON
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Portable Self-Test Ground
®
Cat. No. GSPA2
Rated: 20A-120VAC, 60Hz, 2400W
CAUTIONS:
• The connected load should be turned OFF during a power failure, as this
device will automatically reset when power is restored. This device will
NOT automatically reset after tripping while in use.
• This device protects against current leakage caused by ground faults only.
It does not protect against overcurrent or short circuits.
• This device is suitable for temporary outdoor use; however, DO NOT allow
water or other liquids to infiltrate the device.
• Power will automatically be applied to the load wires when the device
is energized.
Nuts
Écrous
Tuerecas
GROUND
FAULT
OFF
ON
Panel
Panneau
Panel
GFCI
DDFT
ICFT
WIRING DIAGRAM
Schéma de Câblage
Diagrama de Cableado
LINE
Ligne
WHITE
BLACK
Linea
Blanc
Noir
Blanco
Negro
GFCI
DDFT
ICFT
TEST
RESET
FAULT
DETECTION
LOAD-SIDE
POWER
WHITE
BLACK
Blanc
Noir
LOAD
Blanco
Negro
Charge
Carga
DI-001-GSPA2-22A
ENGLISH
Screws
Vis
Tornillos
Outlet
Sortie
Contacto

Publicidad

loading

Resumen de contenidos para Leviton SmartlockPro GSPA2

  • Página 1 LIMITED 2 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option.
  • Página 2 POLÍTICA DE GARANTÍA DE 2 AÑOS: Leviton S de RL de CV, Lago Tana No. 43, Col. Huichapan, Del. M. Hidalgo, Ciudad de México, CP de la date d’achat, avant la fin de la dite période de 2 ans, à...

Este manual también es adecuado para:

Smartlockpro gspa2-y