IMPORTANT: If the boiler is operating while full of ash or residues, that might stretch the burn pot and its
support, the ashtray basket and even the burn pot, being the cause of bad operation or possible breakdown.
This is necessary to ensure correct operation and maintain the stove's life duration. When winter ends,
contact your provider (if he did not contact you) and meet to carry out this maintenance; the following shall be done
(the stove must always be disconnected from power):
5.6.
Review of daily and weekly maintenance points.
5.7.
Cleaning of the heat exchanger. CAUTION! THE BOILER MUST BE UNPLUGGED BEFORE THIS OPERATION
(very important).
Open side doors and remove the screws securing the boiler cover. Once the cover has been removed, open
the upper door for cleaning of the exchanger and the door of the home to gain access to the front cover of
the exchanger, which shall be removed. Once we have full access to the exchanger, tubes shall be cleaned by
using a cleaning brush and applying the cleaning liquid to clean the exchanger, if necessary.
Front cover.
Fireplace door.
Upper door for cleaning of exchanger.
Top cover.
Front cover for cleaning of the exchanger.
Cleaning brush.
Exchanger cleaner.
Top cover.
Upper door for cleaning of exchanger.
Exchanger .
Front cover for cleaning of the exchanger.
Front cover.
Cleaning brush.
Exchanger cleaner.
MAINTENANCE AT END OF SEASON OR EVERY 500 KG OF FUEL.
37
Drawing 15
Drawing 16