Carefully read these instructions and keep them for future reference.
This is a medical device for home use and is specifically designed
Visit our Internet site www.flaem.it to view the whole range of Flaem products
THE UNIT FITTINGS INCLUDE:
A Main unit
A1 - Switch
A2 - Vacuum gauge
A3 - Air inlet port
A4 - Vacuum regulation knob
A5 - Accessory compartment
A6 - Power cord
B Connection tubes (main unit/accessories)
B1 - Short tube
B2 - Long tube
IMPORTANT SAFEGUARD
• Before using the unit for the first time, and periodically throughout its life, check the power supply cord for any damage; if
you detect any damage, do not plug it in. Take the appliance immediately to an authorised service centre or your dealer.
• When used very frequently, we recommend that the nebuliser be replaced every 6 months (or earlier if it becomes clogged), in
order to guarantee the maximum therapeutic effect.
• Children and disabled persons should always use the unit under strict supervision of an adult who has read this manual.
• Several parts of the device are small enough to be swallowed by children; therefore keep the device out of reach of children.
• The unit should not be used in the presence of anaesthetic mixture inflammable with air, oxygen or nitrous oxide.
• Do not use the tubes and the cords of the device for purposes other than those specified as they may cause strangulation hazard;
utmost attention must be paid to children and persons with special needs; usually, such persons are not capable of assessing the
hazard correctly.
• Keep the cord away from heated surfaces.
• Keep the power supply cord away from animals (for example rodents) as they may damage the insulation of the power supply cord.
• Do not handle the unit with wet hands. Do not use the device in humid environments (e.g. while taking a bath or shower). Do not
immerse the device in water; should this accidentally occur, unplug the device immediately. Do not remove or touch the device
immersed in water before pulling out the plug. Take the device immediately to an authorized service center or to your local dealer.
• Only use the device in dust-free environments; otherwise, therapy may be compromised.
• The casing of this unit is not protected against the penetration of liquids. Do not wash the device under running water or submerge
in water. Keep away from splashing water or other liquids.
• Do not expose the device to high temperatures.
• Do not put the device near heat sources, direct sunlight, or in hot environments.
• Do not obstruct or insert any objects in the filter or in its housing in the device.
• Do not obstruct the air slots placed on both sides of the unit.
• During use, always place the unit on a firm surface clear of obstacles.
• Check that there is no material obstructing the air slots before each use.
• Do not place any objects inside the air slots.
• Repairs must be performed by authorized personnel only. Any unauthorized repairs will void the warranty and may pose a safety
hazard for the user.
• The average duration provided for compressor is 700 hours.
WARNING: Do not modify this equipement without authorization of the manufacturer
• The Manufacturer, the Retailer and the Importer are responsible for the safety, reliability and performance of the device only if: a)
the device is used in accordance with the operating instructions b) the electrical system of the premises where the device is used
is in compliance with current laws.
• Never use adaptors for power supplies different from the one indicated on the bottom of the unit (plate details). Keep the cord away
from heated surfaces.
Suction Pump
Suction pump for tracheotomy patients
Congratulations on your purchase and thank you for choosing our unit.
Use the unit only as described in this instruction manual.
for patients who have undergone permanent tracheotomy.
C Accessories - Available as spare parts, code ACO48
C1 - Anti-spill vessel
C1.1 - Anti-spill vessel "A" port (OUT)
C1.2 - Anti-spill vessel "B" port (IN)
C2 - 250 ml collection vessel
C2.1 - Collection vessel "A" port (OUT)
C2.2 - Collection vessel "B" port (IN)
C3 - Manual suction regulator
C4 - Suction cannula
7