SAFETY INFORMATION
When using SignalTEK CT, always take basic safety precautions to reduce the risk of fire, electric
shock and injury to persons. These include the following:
En
INTRODUCTION
Comprehensive testing of installed data cables is essential in order to:
Prove that the cables are capable of carrying Ethernet traffic, error-free in accordance with the
Ethernet standard
Prove that they are correctly wired
Minimise call-backs
Two tests are essential to achieving this quality standard:
A data test which sends Ethernet traffic over the cable and checks that its performance
complies with the IEEE 802.3ab standard
A wiremap test which checks that the wiring is free from faults
SignalTEK CT is a Data Cable Transmission Tester that allows you to:
Perform both of the required tests automatically, measure the cable length, and save the
results, all from a single button press
Review the results, identify any faults found and re-test after repairs if necessary
Create and output a report as documented proof that the cables tested are fit for purpose, and
as a record of the length of cable installed
TEST PRINCIPLE
A typical procedure for testing and documenting a number of cables in a job is:
1. Enter into the tester the details of the engineer performing the tests, and your company logo if
required, for inclusion in the final report
2. Enter into the tester the details of the job, including client details as appropriate and cable
Category if required, for inclusion in the final report
3. For each cable to be tested:
4. When all of the cables have been tested:
3
When connecting to the line, special care must be taken as high voltages may be present
on the line and there may be a danger of electrocution.
Avoid using the tester during an electrical storm - there is a remote risk of electric shock
by lightning.
Use only the mains electricity adaptor supplied with your SignalTEK CT.
DO NOT CONNECT ANY TELECOMMUNICATIONS NETWORK
TO ANY OF THE TESTER'S PORTS
a. Connect the SignalTEK CT Test Unit to one end of the cable
b. Connect the SignalTEK CT Remote Unit to the other end of the cable
c. Press the yellow Autotest button on either Unit
d. Allow the two tests to be completed (approx. 20secs total)
e. Move on to the next cable and repeat steps (a) to (d)
a. (Optional) Review the results, repair and re-test any faulty cables
b. Plug a USB memory key into the Test Unit
c. Save a full or summary report for delivery to the client
SignalTEK CT
156840.02