FCC/IC
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS
standards. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct theinterference by one or more of
the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different to which the receiver is
connected.
— Consult the dealer or an experienced radio/TV technician for help
Important note: To comply with the FCC RF exposure compliance requirements, no change
to the antenna or the device is permitted. Any change to the antenna or the device could result
in the device exceeding the RF exposure requirements and void user's authority to operate
the device.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d'Industrie Canada. Son utilisation est sujette aux deux conditions
suivantes : (1) cet appareil ne doit pas occasionner de brouillage préjudiciable et (2) cet
appareil doit accepter toutes les interférences reçues, notamment les interférences qui peuvent
provoquer un fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de
ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites
ont été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable
en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence
radio et, s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un
brouillage préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que
des interférences ne se produiront pas au sein d'une installation donnée. Si cet appareil
occasionne un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit
d'allumer et d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons
l'utilisateur à essayer de corriger ces interférences en appliquant une ou plusieurs des mesures
suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC
concernant l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est
autorisée. Toute modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le
dispositif dépasse les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur
à utiliser ce dispositif.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC
y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria
de Canadá aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las
siguientes dos condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2)
este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un
funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de
Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en una
instalación residencial. Este equipo genera, usa y puede irradiar energía de radiofrecuencias
y, si no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a las
radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en una
instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción de radio
o televisión, lo que puede determinarse encendiendo y apagando el equipo, se recomienda
que el usuario intente corregir la
interferencia por medio de la implementación de una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Información de
contacto de los Estados Unidos | Partie responsable - Coordonnées des États-Unis
ZW4009:
FCC ID — U2ZZW4009 | IC: 6924A-ZW4009
ZW4009DV:
FCC ID — U2ZZW4009DV | IC: 6924A-ZW4009DV
Jasco Products Company | Model: ZW4009/46563/ZW4009DV/43106
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are trademarks of their
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
respective owners.
DISTRIBUTED BY JASCO PRODUCTS COMPANY LLC,
Tous les noms de marque illustrés sont des
10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114.
marques de commerce de leurs propriétaires
©JASCO 2021 | 46563 | ZW4009 | 43106 | ZW4009DV |
respectifs.
06/02/21 v3
Todas las marcas que aparecen aquí son marcas
registradas de sus respectivos dueños.
1.
1.
Tools you will need
IMPORTANT!
The fixture controlled by the Jasco Z-Wave In-Wall Smart Switch must not
exceed 960W (120VAC)/1385W (277VAC) incandescent. The switch is designed
only for use with permanently installed fixtures.
Getting to know your new Z-Wave device
• Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be included in multiple groups and scenes
• May be used in single-pole installation or with up to four add-on switches (model
46561/45761) in 3-way or 4-way wiring configurations
• Compatible with all incandescent and CFL/LED bulbs
• Auto line/load detection
• Uses a standard, toggle wallplate for single-gang installations (wallplate not
included)
• Z-Wave certified for simple pairing and integrated home automation
• Screw terminal installation — requires wiring connections for line (hot), load,
neutral and ground. Traveler wire required for 3-way or 4-way installation
• This Z-Wave device has advanced features that allow you to customize your
experience. These features can only be adjusted by a Z-Wave enabled controller
that supports the Z-Wave configuration command class. For a complete list of
adjustable configurations, visit www.ezzwave.com/config
2.
2.
A
B
D
F
G
C
E
A. Ground (Green/Bare)
E. Neutral (White)
B. Line or Load (Black)
F. Up — press & release to turn
switch on
C. Line or Load (Black)
G. Down — press & release to turn
D. Traveler (Red/Other)
switch off
MANUAL • MANUEL •
MANUAL
In-Wall
READ IT OR WATCH IT
Smart Switch
Interrupteur
Read instructions or watch easy-to-follow video.
intelligent
mural
Scan QR code or visit https://byjasco.com/46563i
Interruptor
de pared
inteligente
Convert any smart control* to a multi-location switch
*For a list of compatible devices, visit ezzwave.com
Smart Control
Add-on Switches
To purchase an add-on switch or for more
details, visit ezaddonswitch.com.
Each smart control supports
up to 4 add-on switches
ezaddonswitch.com
Purchase additional items at
EZzwave.com, EZzigbee.com or visit your local retailer.
In-Wall
Plug-in
In-Wall
Smart Dimmers
Smart Dimmers
Add-on Switches
In-Wall Motion
Plug-in
In-Wall
Switch or Dimmer
Smart Switches
Smart Switches
Scan to view
installation guide
Enbrighten
In-Wall
Hinge Pin
Balayez ce code pour
Smart LED Bulb
Smart Fan Control
Smart Door Sensor
consulter le guide
d'installation.
Escanear para ver
ezzwave.com
la guía de instalación
Z-Wave
Certified
Wireless Lighting Control
®
Direct Wire,
Portable
In-Wall
Certifié Z-Wave
Commande d'éclairage sans fil
®
40A Outdoor
Smart Multi
Tamper-Resistant
Outdoor Smart
Control inalámbrico para iluminación certificado
por Z-Wave
®
Smart Switch
Sensor
Smart Outlet
3.
3.
OR
OR
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the
service panel. All wiring connections must be made with the POWER OFF to
avoid personal injury and/or damage to the switch. This device is intended for
installation in accordance with the National Electric Code and local regulations
in the United States or the Canadian Electrical Code and local regulations in
Canada. If you are unsure or uncomfortable about performing this installation,
consult a qualified electrician.
Multi-switch wiring
For 3-way installations, please refer to add-on switch (46561/45761) manual.
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wallplate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT disconnect the
wires.
5. There are up to five screw terminals on the switch; these are marked:
A. GROUND — Green/Bare
B. LINE or LOAD — Black (connected to power or lighting)
C. LINE or LOAD — Black (connected to power or lighting)
D. TRAVELER — Red/Other (only in 3-way installations)
4.
4.
Adding your device to a Z-Wave network:
1. Follow the instructions for your Z-Wave certified controller to add a device to the
Z-Wave network.
2. Once the controller is ready to add your device, press up and release the toggle.
Please reference the controller's manual for instructions.
You have complete control to turn your fixture ON/OFF according to groups,
scenes, schedules and interactive automations programmed by your controller.
If your Z-Wave certified controller features remote access, you can control your
fixture from your mobile devices. If prompted by the controller to enter the S2
security code, refer to the QR code/security number on the side of the box or the QR
code label on the product (see Figure 1). Enter the 5-digit pin code.
DSK :
Figure 1.
Z-WAVE DSK
XXXXX
-25651-22671
-26939-47599
-19612-25872
PIN: XXXXX
-47752
DO NOT RETURN THIS
PRODUCT TO THE STORE
STOP
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
Questions? Contact our U.S.-based Consumer Care at 1-800-654-8483 between
7AM-8PM, M-F, Central Time.
46563
For the most up-to-date product support, accessories, electronic (PDF) format manuals
ZW4009
and more, visit www.byjasco.com/support.
43106
• No user-serviceable parts in this unit.
ZW4009DV
Si vous avez des problèmes ou des questions, communiquez avec notre
équipe de soutien technique au 1-800-654-8483, option 1, du lundi au vendredi,
de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels en format
électronique (PDF) et plus encore, visitez le site
www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo técnico al número:
1-800-654-8483, opción 1, de lunes a viernes, de 7 a.m. a 8 p.m., hora estándar
del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES
CONTROL DE EQUIPOS
CAUTION:
ELECTRODOMÉSTICOS
PRECAUCIÓN:
DO NOT EXCEED RATINGS
USAR EXCLUSIVAMENTE PARA CONTROLAR
DO NOT USE TO CONTROL ANY DEVICE
BOMBILLAS CFL/LED INCANDESCENTES O
WHERE UNINTENDED OPERATION COULD
ATENUABLES
CAUSE UNSAFE CONDITIONS (HEAT LAMP , SUN
LAMP , ETC.)
NO SUPERE LOS VALORES NOMINALES
ELÉCTRICOS
DO NOT USE TO CONTROL RECEPTACLES
NO USAR PARA CONTROLAR DISPOSITIVOS
FOR INDOOR USE ONLY
EN LOS QUE EL FUNCIONAMIENTO NO
INTENCIONADO PODRÍA PROVOCAR
AVERTISSEMENT
SITUACIONES PELIGROSAS (LÁMPARAS DE
CALEFACCIÓN, LÁMPARAS SOLARES, ETC.)
NO UTILICE PARA CONTROLAR
RISQUE D'INCENDIE
TOMACORRIENTES
RISQUE DE CHOC ÉLECTRIQUE
USE SOLAMENTE EN INTERIORES
RISQUE DE BRÛLURES
COMMANDE DES APPAREILS
NOT FOR USE WITH MEDICAL OR LIFE-
ATTENTION:
SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE
UTILISER SEULEMENT POUR COMMANDER
LES AMPOULES À DEL ET FLUOCOMPACTES À
USED TO SUPPLY POWER TO OR CONTROL THE
INCANDESCENCE OU À INTENSITÉ RÉGLABLE
ON/OFF STATUS OF MEDICAL OR LIFE-SUPPORT
EQUIPMENT.
NE PAS DÉPASSER LES CARACTÉRISTIQUES
NOMINALES
NE PAS UTILISER AVEC UN ÉQUIPEMENT
NE PAS UTILISER POUR COMMANDER
DES APPAREILS POUR LESQUELS UN
MÉDICAL OU DE SURVIE
FONCTIONNEMENT IMPRÉVU POURRAIT
LES DISPOSITIFS COMPATIBLES AVEC LA
ENTRAÎNER DES CONDITIONS DANGEREUSES
TECHNOLOGIE Z-WAVE NE DEVRAIENT
(LAMPE À RAYONS INFRAROUGES, LAMPE
JAMAIS ÊTRE UTILISÉS POUR ALIMENTER OU
SOLAIRE, ETC.)
COMMANDER LA MISE EN MARCHE OU L'ARRÊT
DE L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
NE PAS UTILISER POUR COMMANDER LES
PRISES DE COURANT
POUR UTILISATION INTÉRIEURE UNIQUEMENT
SE PROHÍBE SU EMPLEO EN
EQUIPO MÉDICO O EQUIPO PARA EL
MANTENIMIENTO DE LAS FUNCIONES
VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN
USAR PARA SUMINISTRAR ENERGÍA ELÉCTRICA
AL EQUIPO MÉDICO O AL EQUIPO PARA EL
MANTENIMIENTO DE FUNCIONES VITALES, NI
PARA CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DE DICHOS EQUIPOS.
Plug-in
14319
ZW4003
Switch
Insert wires into holes, do not wrap wires
Out to Light (Load)
around screws. Do not remove screws.
B
A
D
E
C
From Breaker Box
E. NEUTRAL — White
Match these screw terminals to the wires connected to the existing switch.
6. Disconnect the wires from the existing switch. Label wires according to the
previous terminal connection.
Observe important wiring information
IMPORTANT! This switch is rated for and intended to only be used with copper wire.
Wire gauge requirements
Use 14AWG or larger wires suitable for at least 80°C for supplying line (hot), load,
neutral, ground and traveler connections.
Wire strip length
Attach using the enclosure's holes, strip insulation 5/8in. (16mm).
UL specifies the tightening torque for the screws is 14Kgf-cm (12lbf-in).
1. Connect the green or bare copper ground wire to the GROUND terminal.
2. Connect the black wire from the light to either LINE/LOAD terminal.
3. Connect the black wire from the electrical service panel (hot) to the other
LINE/LOAD terminal.
4. Connect the white wire to the NEUTRAL terminal (use jumper wire if needed).
NOTE: The traveler terminal is only used for 3-way or 4-way wiring and should remain
unused if the switch is installed in a 2-way system (one switch & one load).
5. Insert switch into the switch box being careful not to pinch or crush wires.
6. Switch must be independently mounted (vertical position only).
To remove and reset the device:
1. Follow the instructions for your Z-Wave certified controller to remove a device
from the Z-Wave network.
2. Once the controller is ready to remove your device, press up and release the
toggle.
To return your switch to factory defaults:
Quickly press ON (up) button three times, then immediately press the OFF (down)
button three times.
NOTE: This should only be used if your network's primary controller is missing or
otherwise inoperable.
NOTE: SmartStart enabled products can be added into a Z-Wave network by
scanning the QR code on the product with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product will be added
automatically within 10 minutes of being switched on in the network vicinity.
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects five years
from the original date of consumer purchase. This warranty is limited to the repair or replacement of
this product only and does not extend to consequential or incidental damage to other products that
may be used with this product. This warranty is in lieu of all other warranties, expressed or implied.
Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion
or limitation of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from state
to state. Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between
7AM – 8PM CT or www.byjasco.com if the unit should prove defective within the warranty period.
GARANTIE
Jasco Products Company garantit que ce produit est exempt de défauts de fabrication pour une période
de cinq ans à compter de la date de l'achat original par l'acheteur. Cette garantie se limite exclusivement
à la réparation ou au remplacement de ce produit et n'est pas applicable aux dommages indirects ou
accessoires survenus sur d'autres produits utilisés avec ce produit. Cette garantie se substitue à toute
autre garantie expresse ou implicite. Certains États ne permettent pas de restrictions quant à la durée
d'une garantie implicite ou permettent l'exclusion ou la limitation des dommages indirects et accessoires;
il se peut, par conséquent, que cette garantie ne s'applique pas dans votre cas. Cette garantie vous
confère des droits juridiques précis; vous pouvez jouir d'autres droits qui peuvent varier d'un État à l'autre.
Veuillez communiquer avec notre service à la clientèle aux États-Unis au 1-800-654-8483 (option 1) entre
7 h et 20 h (HNC) ou www.byjasco.com si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
Jasco Products Company garantiza que este producto está libre de defectos de fabricación por un
período de cinco años a partir de la fecha original de compra del consumidor original. Esta garantía se
limita a la reparación o reposición de este producto y no cubre daños indirectos o incidentales a otros
productos que se pudieran utilizar con este producto. Esta garantía reemplaza cualquier otra garantía
explícita o implícita. Algunos estados no permiten la aplicación de limitaciones respecto de la duración
de una garantía implícita o permiten la exclusión o limitación de la cláusula sobre daños indirectos o
incidentales, por este motivo las limitaciones arriba mencionadas pueden no aplicarse en su caso.
Esta garantía le otorga derechos específicos y es posible que tenga otros derechos que pueden variar
según el estado en el que vive. Por favor, comuníquese con nuestro Centro de atención al cliente con
sede en EE. UU. al 1-800-654-8483 (opción 1) entre las 7.00 a 20.00 h, hora estándar del centro (CST)
o www.byjasco.com en caso de que se produzca algún defecto durante la vigencia de la garantía.
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW4009
Power: 120VAC, 60Hz
Signal (frequency): 908.4/916MHz
Maximum loads: 960W incandescent, 1/2HP motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
Operating temperature range: 32-104° F (0-40° C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action,
pollution degree (2), impulse voltage (2500V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4009
Tension : 120VCA, 60Hz
Signal (fréquence) : 908.4/916MHz
Charges maximales : 960W incandescent, moteur de 1/2HP ou résistance de 1800W (15A)
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant
jusqu'à 150 pi (45.7m)
Plage de températures de fonctionnement : De 0 à 40° C (de 32 à 104° F)
Utilisation intérieure uniquement
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de changements
sans préavis
ESPECIFICACIONES
ZW4009
Energía: 120VCA, 60Hz
Señal (frecuencia): 908.4/916MHz
Cargas máximas: 960W incandescente, 1/2HP motor o 1800W (15A) resistiva
Alcance: Hasta 150 pies (45.7m) en línea de visibilidad directa entre el control inalámbrico y el módulo
receptor Z-Wave más cercano
Rango de temperatura de funcionamiento: 0-40° C (32-104° F)
Para uso en espacios interiores solamente
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
SPECIFICATIONS
ZW4009DV
Power: 120/277VAC, 60Hz
Signal (frequency): 908.4/916MHz
Maximum loads: 960W (120VAC)/1385W (277VAC) incandescent, 1/2HP (120/277VAC) motor or
1800W (15A) (120VAC)/15A (277VAC) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
Operating temperature range: 32-104° F (0-40° C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action,
pollution degree (2), impulse voltage (4000V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4009DV
Tension : 120/277VCA, 60Hz
Signal (fréquence) : 908.4/916MHz
Charges maximales : 960W (120VCA)/1385W (277VCA) incandescent, moteur de 1/2HP (120/277VCA)
ou résistance de 1800W (15A) (120VCA)/15A (277VCA)
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant
jusqu'à 150 pi (45.7m).
Plage de températures de fonctionnement : De 0 à 40° C (de 32 à 104° F)
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de changements
sans préavis
ESPECIFICACIONES
ZW4009DV
Energía: 120/277VCA, 60Hz
Señal (frecuencia): 908.4/916MHz
Cargas máximas: 960W (120VCA)/1385W (277VCA) incandescente, 1/2HP (120/277VCA) motor o
1800W (15A) (120VCA)/15A (277VCA) resistiva
Alcance: Hasta 150 pies (45.7m) en línea de visibilidad directa entre el control inalámbrico y el módulo
receptor Z-Wave más cercano
Rango de temperatura de funcionamiento: 0-40° C (32-104° F)
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
Out to Light (Load)
B
A
D
E
C
From Breaker Box
7. Secure the switch to the box using the supplied screws.
8. Mount the wallplate.
9. Reapply power to the circuit at fuse box or circuit breaker and test the
system.
Basic operation
The connected light can be turned ON/OFF in two ways:
1. Manually from the front panel of the switch.
2. Remotely with a Z-Wave controller.
Manual control
The switch allows the user to turn ON/OFF the connected fixture.
1. To turn the connected fixture ON, press up and release the toggle.
2. To turn the connected fixture OFF, press down and release the toggle.
Cycle LED light
An LED shines behind the toggle to act as a guide light or status indicator.
How to cycle between options: Press up three times, then down one time quickly
1. LED is OFF all the time (default)
2. LED is ON all of the time (illuminates switch in the dark)
3. LED is ON when the load is OFF (guide light in the dark)
4. LED is ON when the load is ON (indicates the switch is ON)
Add-on switch (46561/45761) is required for multi-switch 3-way or 4-way installations.
Connecting the traveler terminal of this switch to a standard switch will cause damage or result in
improper function. If this switch is a part of a multi-switch installation, do not connect the traveler
wire or apply power until add-on switches are correctly installed. For more information on 3-way or
4-way installations, view the manual with the add-on switch (46561/45761).
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave
network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
• This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled with the local load
• Association Group 3 supports Basic Set and is controlled by double pressing the
ON or OFF button
• Each Association Group supports 5 total nodes