GENERAL RECOMMENDATIONS
GENERAL RECOMMENDATIONS FOR THE INSTALLER
•
Installation, start-up and maintenance of the appliance should be
carried out by qualified engineers, licensed fitters or personnel
authorised by the manufacturer.
•
Carefully read the recommendations in this instruction booklet, as they
provide important advice for safe installation, operation and
maintenance.
•
Keep this booklet to hand in a safe place for future reference.
•
This appliance should be used only for the purpose for which it has been
expressly designed, keeping it warm any other use should be considered
incorrect and therefore dangerous.
•
After having unpacked the appliance, check that it is in perfect condition.
If in doubt, do not use the appliance and contact authorised personnel.
•
Do not leave any packing material within reach of children, as it is a potential source of danger.
•
Before connecting the appliance, make sure that the data on the rating plate (at the rear towards the bottom) correspond to the
mains supply data (electricity).
•
In case of failure or malfunctioning, turn off the appliance immediately.
TECHNICAL DATA
Model (type)
HHT052E (HHT052E)
HHT081E (HHT081E)
HHT082E (HHT082E)
HHT161E (HHT161E)
HHT162E (HHT162E)
HHT282E (HHT282E)
Operating
Model (type)
temperature
(° C)
HHT052E
(HHT052E)
HHT081E
(HHT081E)
HHT082E
(HHT082E)
30 ÷ 120
HHT161E
(HHT161E)
HHT162E
(HHT162E)
HHT282E
(HHT282E)
AND TECHNICAL DATA
Rated voltage
Total input
[Vac]
230
Tray capacity:
distance [mm]
5 x GN 2/1 (70)
5 x 65 (h)
10 x GN 1/1 (70)
10 x 65 (h)
8 x GN 1/1 (70)
8 x 65 (h)
8 x GN 2/1 (70)
8 x 65 (h)
16 x GN 1/1 (70)
16 x 65 (h)
16 x GN 1/1 (70)
16 x 65 (h)
16 x GN 2/1 (70)
16 x 65 (h)
32 x GN 1/1 (70)
32 x 65 (h)
8 x GN 2/1 (70)
8 x 65 (h)
+
+
8 x GN 2/1 (70)
8 x 65 (h)
Amps.
[kW]
[A]
1,5
6,5
1
4,4
1,5
6,5
2
8,7
3
13,0
3
13,0
Tray max. height [mm]
1 x 200 (h)
2 x 150 (h)
+ 2 x 65 (h)
2 x 200 (h)
4 x 150 (h)
+ 4 x 65 (h)
2 x 200 (h)
3 x 150 (h)
+ 2 x 65 (h)
2 x 200 (h)
3 x 150 (h)
+ 2 x 65 (h)
4 x 200 (h)
6 x 150 (h)
+ 4 x 65 (h)
4 x 200 (h)
6 x 150 (h)
+ 4 x 65 (h)
4 x 200 (h)
6 x 150 (h)
+ 4 x 65 (h)
8 x 200 (h)
12 x 150 (h)
+ 8 x 65 (h)
2 x 200 (h)
3 x 150 (h)
+ 2 x 65 (h)
+
3 x 150 (h)
2 x 200 (h)
+ 2 x 65 (h)
8
Example of rating plate
Cable according to IEC-60245-57
(H05RN-F or HO7RN-F). Minimum
cross section of connection cable
[mm2]
3 x 1
3 x 1,5
Maximum total load
(product + trays) h65
GN1/1) [kg]
36 + 15
29 + 12
58 + 24
58 + 24
115 + 48
+
115 + 48
GB
Ed. 0314
Weight when
empty [kg]
51
46
62
88
106
111