ASSEMBLY INSTRUCTIONS
1. DISCONNECT THE POWER AT THE MAIN
FUSE BOX.
Installing the Mounting Bracket
2. Position mounting bracket so threaded ends of
attached mounting screws are facing out.
3. Carefully pull the house wires through the large
hole in the mounting bracket (A).
4. Align the small holes in the mounting bracket (A)
with the holes in the junction box.
5. Thread each junction box screw (BB) into
appropriate hole in mounting bracket (A) and
into hole in junction box. Tighten screws (BB) to
attach mounting bracket (A) to junction box.
CAUTION: Make sure house wires are pulled
completely through hole in mounting bracket (A). Do
not pinch wires between mounting bracket (A) and
wall.
Connecting the Wires
6. Strip 3/4" of insulation from ends of fixture wires.
7. Slightly loosen ground screw on mounting
bracket (A). Do not completely remove ground
screw. Wrap house ground wire (copper) around
ground screw, leaving enough ground wire to
attach to fixture ground wire. Twist end of fixture
ground wire and end of house ground wire
together. Twist wire connector (AA) onto ends of
wires. Completely tighten wire connector (AA).
Reference chart to the right for correct wire
connections.
steps 2-5
FIXTURE
MOUNTING
SCREW
steps 6-7
HOUSE GROUND
WIRE (COPPER)
GROUND
SCREW
A
Connect Supply (House) Ground Copper Wire to:
Bare Copper Wire or,
Bare Silver Wire or,
Green Insulated Wire.
5
JUNCTION
BOX
BB
AA
FIXTURE
GROUND WIRE
A