Installation Height: 1.8-2.5m wall
Time Delay: Min.10sec±3sec
Detection Moving Speed: 0.6-1.5m/s
Max. 7min±2min
Protection class against electric shock: II
IP Class: IP44
INSTALLATION: (see the diagram) • Shut off power. • Loosen the screw on the bottom
lid, open the wiring hole, pass the wire of power and load through the bottom lid.
• Fix the bottom lid with inflated screw on the selected position. • Connect the power
and load wire into connection-wire column according to the connecting figure.
• Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it.
CONNECTION-WIRE DIAGRAM: (See the right figure)
TEST: Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob
clockwise on the maximum (sun). • Switch on the power; the sensor and its connected
lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start
work .If the sensor receives the induction signal, the lamp will turn on. While there is no
another induction signal any more, the load should stop working within 10sec and the
lamp would turn off. • Turn LUX knob anti-clockwise on the minimum (-). If the ambient
light is more than 3LUX, the sensor would not work and the lamp stop working too. If the
ambient light is less than 3LUX (darkness), the sensor would work. Under no induction
signal condition, the sensor should stop working within 10sec
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work! If the lamp is more than 60W, the distance between lamp
and sensor should be 60cm at least.
NOTES: This product should only be installed by qualified electrician!
This product should not be installed on an unstable surface! Don't place any objects in
front of the detection window as they will interfere with the detection operation. Avoid
installing it near air temperature alteration zones for example: air conditioners, central
heating, etc. For your safety. Please don't open this product before switching off the
power completely. In order to avoid the unexpected damage of product, please add a
safe device of 6A when installing infrared sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY:
The load does not work: a. Please check if the connection of power source and load
is correct. b. Please check if the load is good. c. Please check if the settings of working
light correspond to ambient light.
The sensitivity is poor: a. Please check if there is any hindrance in front of the detector
to affect it to receive the signals. b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field. d. Please check if
the installation height corresponds to the height required in the instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically: a. Please check if there is continual
signal in the detection field. b. Please check if the time delay is set to the maximum
position c. Please check if the power corresponds to the instruction.
DISPOSAL: The device is marked with the symbol of a crossed-out rubbish container, in
accordance with the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment
(WEEE). Products marked with this symbol should not be recycled or disposed of with
other household waste at the end of their useful life. The user is obliged to dispose of waste
electrical and electronic equipment by delivering it to a designated point where it is recycled.
For information on where and how to dispose of used electrical and electronic equipment in
an environmentally safe manner, the user should contact the relevant local authority, the waste
collection point or the point of sale where they purchased the equipment.
PL
Czujnik ruchu na podczerwień
Urządzenie to wykazuje wysoką czułość oraz posiada wbudowany układ scalony SMT.
Zapewnia automatykę, wygodę, bezpieczeństwo oraz oszczędność energii. Źródłem
sygnału włączającego urządzenie są promienie podczerwone wysyłane naturalnie
przez człowieka. W momencie gdy źródło sygnału znajdzie się w polu detekcji,
urządzenie włączy się po wcześniejszym automatycznym rozpoznaniu dnia oraz nocy.
Urządzenie jest łatwe w instalacji oraz może być szeroko zastosowane.
SPECYFIKACJA:
Zasilanie: 220-240V/AC
Obszar detekcji: 180°
Częstotliwość: 50/60Hz
Temperatura pracy: -20/+40°C
Czujnik oświetlenia:<3-2000LUX (regul.)
Dopuszczalna wilgotność: <93% RH
Ochrona przeciw porażeniem elektrycz.: II
FUNKCJE:
Funkcja rozróżniania dnia oraz nocy: Użytkownik może dostosować pracę urządzenia
do światła otoczenia. Urządzenie pracuje zarówno w dzień jak i w nocy gdy pokrętło
jest ustawione w pozycji „+" (max). Urządzenie pracuje w świetle otoczenia mniejszym
niż 3 LUX gdy pokrętło jest ustawione w pozycji „-" (min).
W celu odpowiedniego ustawienia prosimy zapoznać się z sekcją „TEST".
- Opóźnienie czasowe: Po odebraniu drugiego sygnału indukcyjnego po pierwszym
sygnale, obliczy ono czas jeszcze raz na podstawie pierwszego opóźnienia.
Instalacja (patrz diagram): Wyłącz zasilanie. • Odkręć śruby w dolnej pokrywie, przez
otwór w dolnej części czujnika przeprowadź przewód zasilający. • Zamontuj pokrywę
i umocuj w wybranej pozycji za pomocą dołączonych śrub. • Podłącz przewód
zasilający do kostki przyłączeniowej zgodnie z schematem połączeń.
MCE358
Opóźnienie czasowe: min. 10sek (+/- 3sek.)
max. 7min. (+/- 2min)
Wysokość instalacji: 1.8-2.5m
Prędkość detekcji ruchu: 0.6~1.5m/s
Obciążenie max.
1200W
300W
Dystans detekcji: max. 12m (<24°C)