Performance Data Sheets - Sears Kenmore 106.7200 Serie Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PERFORMANCE DATA SHEETS
Interior Water Filtration System
Model 46 9006-750
Capacity
750 Gallons
(2839 Liters)
System tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the
reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead, Mercury, Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts, Turbidity, Asbestos,
Tetrachloroethylene
and Lindane.
This system
has been
tested
according
to NSF/ANSI
Standards 42 and 53 for the reduction
of the substances
listed
below.
The
concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than
or equal
to the
permissible
limit
for water
leaving
the system,
as specified
in NSF/ANSI
Standards 42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.00 mg/L
2.0 mg/L + 10%
0.06 mg/L
**
0.050625 mg/L
97.00%
97.52%
Particulate Class I*
85% reduction
14,000,000 #/mL
Atparticles/mLleast
10,000
370,000 #/mL
196,666 #/mL
97.40%
99.00%
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
0.150 mg/U
0.15 mg/L + 10%
< 0.001 mg/L
< 0.001 mg/L
>99.30%
>99.30%
Lead: @ pH 8.5
0.010 mg/L
0.150 mg/U
0.15 mg/L _+10%
< 0.001 mg/L
< 0.001 mg/L
>99.30%
>99.30%
Mercury: @ pH 6.5
0.002 mg/L
0.006 mg/L
0.006 mg/L + 10%
0.0005 mg/L
0.0003 mg/L
91.70%
95.00%
Mercury: @ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0018 mg/L
0.00073 mg/L
69.20%
88.10%
Benzene
0.005 mg/L
0.0133 mg/L
0.015 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
96.10%
96.30%
p-Dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L
>99.80%
>99.80%
Carbofuran
0.040 mg/L
0.0753 mg/L
0.08 mg/L _+10%
0.027 mg/L
0.008 mg/L
64.60%
73.45%
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 _+10%
< 0.001 mg/L
< 0.001 mg/L
>93.3%
>93.3%
Atrazine
0.003 mg/L
0.0102 mg/L
0.009 mg/L _+10%
0.0027 mg/L
0.00105 mg/L
76.30%
89.40%
Asbestos
>99%
126.5 MF/L
107to 108fibers/U _
< 0.17 MF/L
< 0.17 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
122,500 #/L
50,O00/L min.
< 1 #/U
< 1 #/U
>99.99%
>99.99%
Turbidity
0.5 NTU
10.5 NTU
11 _+1 NTU
0.30 NTU
0.125 NTU
97.30%
98.80%
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 _+10%
< 0.00016 mg/L
0.000035 mg/L
91.80%
97.90%
Tetrachloroethylene
0.005 mg/L
0.015 mg/L
0.015 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L
>96.6%
>96.6%
Test Parameters:
pH = 7.5 ___ 0.5 unless otherwise
noted.
___ 5°F (20°C
___ 3°C).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
The disposable
water
filter
should
be replaced
at least every
6 months.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90°/0 of the filter's rated life is used, the yellow
(Order) light comes on. When 100% of the filter's rated life
is used, the red (Replace) light comes on, and it is
recommended
that you replace the filter. For models without
filter status lights, replace the filter every 6 months. Use
replacement
filter model 46 9006-750.
2010 suggested
retail price of $44.99
U.S.A./S49.95
Canada. Prices are
subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate
disinfection
before or
after the system. Systems certified for cyst reduction may be
used on disinfected
waters that may contain filterable
cysts.
Flow = 0.78
gpm
(2.9 Lpm). Pressure
= 60 psig (413.7
kPa). Temp.
= 68°F
Refer to the "Water
Filtration
System"
section
for the
Manufacturer's
name
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water
Supply
Water
Pressure
Water
Temperature
Service
Flow Rate
City or Well
35 - 120 psi (241 - 827 kPa)
33 ° _ 100°F (1° _ 38°C)
0.78
gpm
(2.9 L/min.)
@ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore 106.7201 serie

Tabla de contenido