FOAM SLEEVE INSTALLATION AND CLEANING:
1. Disconnect the plug from the wall outlet. With tank cover in an upside down
position, slide foam sleeve down over lid cage pulling until foam sleeve
completely covers lid cage. FIGURE 13.
2. To clean the foam sleeve. Disconnect the plug from the wall outlet. Remove
the tank cover and place the cover in an upside-down position. Remove foam
sleeve by sliding it up and off the lid cage.
3. Shake excess debris off of the foam sleeve with a rapid up and down
movement.
4. Hold foam sleeve under running water for a minute or two, rinsing from the
inside of the filter. A water wash is not always required, depending on the
condition of the foam sleeve.
5. Check the filter for tears. If any are found, replace with a new filter.
1. Your vacuum can be used as a powerful blower. To use your unit as a blower,
clear hose of any obstructions. Remove air diffuser. Insert hose end with
locking nut into blower port and tighten locking-nut. FIGURE 1. Do not over-
tighten. Caution should be used when using as a blower due to the powerful
force of air when using certain attachments.
WARNING!
TO PREVENT ROCKS OR DEBRIS FROM BLOWING OR
RICOCHETING INTO THE EYES OR FACE WHICH CAN RESULT IN
SERIOUS INJURY.
1. The vacuum is equipped with an automatic suction shut-off that operates
when picking up liquids. As the level of the liquid rises in the tank, an internal
float rises until it seats itself against a seal at the intake of the motor, shutting
off suction. When this happens, the motor will develop a higher than normal
pitch noise and the suction is drastically reduced. If this occurs, turn unit off
immediately. Failure to turn unit off after float rises and shuts off suction will
result in extensive damage to the motor. To continue use, empty the liquid
waste from the tank as outlined in the next section.
NOTE: IF ACCIDENTALLY TIPPED OVER, THE VACUUM COULD LOSE
SUCTION. IF THIS OCCURS, TURN UNIT OFF AND PLACE VAC IN UPRIGHT
POSITION. THIS WILL ALLOW THE FLOAT TO RETURN TO ITS NORMAL
POSITION, AND YOU WILL BE ABLE TO CONTINUE OPERATION.
BLOWER FEATURE
AUTOMATIC SUCTION SHUT-OFF
1
ALWAYS WEAR EYE PROTECTION
9

Publicidad