NOTE:
During
this time the room
humidity
level will continue
to be
monitored
and the humidifier
will cycle
the fan on and off until the filter is
completely
dry. The fan will shut off
leaving
you with a dry humidifier
that is
less prone to mold and mildew
growth.
If DRY OUT MODE
is not desired,
refill
the humidifier
with water
and the fan will
return
to the set speed.
NOTE:
Fan automatically
switches
to
lowest
speed
during
DRY OUT MODE.
Check
Filter
indicator
The ability of any humidifier
to efficiently
supply
humidity
output
relies heavily
on the
condition
of the filter. As the filter loads with
impurities
it gradually
loses its wicking
capability.
When this happens,
moisture
output
is reduced
and the humidifier
has to
work longer to satisfy the selected
setting.
This humidifier
has a check filter reminder
timed to appear
after 720 hours of
operation.
When the display shows an
alternating
"CF"
and "room humidity"
setting
at 5 second
intervals
it is a
reminder
to check the filter condition.
NOTE:
Some areas have high water
mineral
content
causing
the need for more
frequent
filter changes.
Refer to "Replacement
and Care of Filter"
on page
10. If a build-up
of deposits
or
severe discoloration
is evident
replace
the
filter to restore maximum
efficiency.
Check
Filter /
Display
Humidistat
The humidistat
located
on the power
cord
senses
the percentage
of humidity
in the
air. It causes
the humidifier
to cycle on
and off to maintain
the selected
humidity
SET point.
The fan will turn on if the
"ROOM"
reading
falls 3% below
the SET
point and will continue
to run the
humidifier
until a reading
of 1% above
the
SET point
is achieved.
The fan will turn
off until the ROOM
reading
falls 3%
below
the SET
point again.
Control
Lock
Out
To avoid
unwanted
tampering
with the
humidifier
settings
the controls
can be
locked.
Activation
Procedure
After the humidifier
functions
have been
set up, hold the power
button
down for 5
seconds.
The display
will show
"CL"
for
2 seconds;
release
the power
button
and
the control
will resume
the display
of the
room humidity.
The room humidifier
will
continue
to function
with the locked
in
settings.
If buttons
are operated
while
"CL"
is active,
the "CL"
is displayed
and
settings
are unaffected.
Deactivation
Procedure
To deactivate
the "CL"
function
simply
press
and hold the power
button
for 5
seconds.
"CL"
will flash at the rate of
1 second
on and 1 second
off for a
period
of 2 seconds
and then resume
the
display
of room humidity.
NOTE:
Be sure
humidistat
located
approximately
4 inches
outside
humidifier
body on power
cord
is free from
obstruction
and away
from any hot air
register.