2.6.2 Overheating Protection (overheating protection temperature can only
be set when in cooling mode)
Press
temperature (+0,5 °C to 35,0 °C) press OK to confirm and exit. (Default
setting: 30,0 °C).
2.7 Differential temperature
Press
Press OK to confirm and exit. (Default setting: 1,0 °C).
2.8 Temperature Monitoring (select the temperature monitoring sensor)
Press
Ambient Sensor + Floor Probe). Press OK to select or
Note: When the thermostat is "on", Floor Probe is automatically detected. In the
event of a Probe error, an error message will appear on the thermostat.
40
Note: Antifreeze Protection operates even when the thermostat is "off".
This protective functionality switches the Heating system "on" when the
ambient temperature reaches the minimum temperature set.
or
Note: Protection against overheating operates even when the thermostat is
"off". This protective functionality switches the Cooling system "on" when
the ambient temperature reaches the maximum temperature set.
or
to select the desired differential temperature (0,5 °C to 3,0 °C).
to navigate between options (Ambient Sensor, Floor Probe or
to select the desired Overheating Protection